Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ESCOBAR RESTAURANT AND TAPAS LLC

Monitoring inspection · Health discipline

On , OSHA opened a monitoring health inspection of ESCOBAR RESTAURANT AND TAPAS LLC in 1140 MOUNT ZION ROAD, MORROW, GA 30260 (NAICS 722511). OSHA activity number 345794960.

Watch Escobar Restaurant AND Tapas LLC — free Get an email when a new federal OSHA severe-injury report for Escobar Restaurant AND Tapas LLC is published. One employer, no account, unsubscribe in one click.
Site address
1140 MOUNT ZION ROAD
City
MORROW
State
GA
ZIP
30260
Mailing
1140 MOUNT ZION ROAD, MORROW, GA 30260
Inspection type
Monitoring (D)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
722511
Employees
21
Ownership type
A

10 citations on file for this inspection.

1910.28 B03 II

Serious Gravity 5 1 instance 21 exposed
Issued
Penalty
Initial $6164.00 · Current $6164.00
29 CFR  1910.28(b)(3)(ii): The employer did not ensure that each employee be protected from tripping into or stepping into or through any hole that is less than 4 feet (1.2 m) above a lower level by covers or guardrail systems.   a) Dish Pit; On or about February 22, 2022, and at times prior, the employer exposed employees to trip hazards, in that the floor drain cover had been removed creating an open floor hole while employees traveled in and out of the kitchen area.
Recent events (1)
  • — Z (S) $6164

1910.37 A03

Serious Gravity 1 1 instance 21 exposed
Issued
Abate by
Penalty
Initial $4351.00 · Current $4351.00
29 CFR  1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  a) Near Bathrooms: On or about February 22, 2022 and at times prior, the employer exposed employees to fire hazards, in that the emergency exit was blocked with cleaning materials, restaurant mats and chairs, obstructing egress in the event of an emergency.
Recent events (1)
  • — Z (S) $4351

1910.303 F02

Serious Gravity 5 1 instance 21 exposed
Issued
Abate by
Penalty
Initial $5801.00 · Current $5801.00
29 CFR  1910.303(f)(2):Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  a) Kitchen; On or about February 22, 2022 and at times prior, employer exposed employees to electrical hazards, in that electrical panels did not contain markings to indicate the purpose of the breakers. Employees use the panel to turn power on and off to the kitchen and exterior.
Recent events (1)
  • — Z (S) $5801

1910.303 G01 II

Serious Gravity 1 1 instance 21 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(g)(1)(ii):The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  a) Kitchen; On or about February 22, 2022 and at times prior, the employer exposed employees to electrical hazards, in that shelving units were stored in front of the electrical panels blocking access to the electrical panels.
Recent events (1)
  • — Z (S) $0

1910.1200 E01

Serious Gravity 1 1 instance 21 exposed
Issued
Abate by
Penalty
Initial $4351.00 · Current $4351.00
29 CFR  1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:   a) Kitchen; On or about February 22, 2022 and at times prior, the employer exposed employees to chemical hazards, in that the employer has not developed or implemented a written hazard communication program for chemicals such as but not limited to Signet Heavy Duty Floor Cleaner/Degreaser and Odoban.
Recent events (1)
  • — Z (S) $4351

1910.1200 F06 I

Serious Gravity 1 1 instance 21 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(f)(6)(i): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v)  a) Kitchen; On or about February 22, 2022 and at times prior, the employer exposed employees to chemical hazards, in that the employer did not ensure that a secondary bottle of Odoban contained the hazard categories of the chemical.
Recent events (1)
  • — Z (S) $0

1910.1200 H01

Serious Gravity 1 1 instance 21 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(h)(1):Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) Kitchen; On or about February 22, 2022 and at times prior, the employer exposed employees to chemical hazards, in that the employer did not train their employees on the hazards of chemicals such as but not limited to Odoban and Signet Heavy Duty Cleaner/Degreaser.
Recent events (1)
  • — Z (S) $0

1910.157 C01

Other-than-serious 1 instance 21 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.157(c)(1):Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a) Back of House/Kitchen: On or about February 22, 2022 and at times prior, employees were exposed to fire hazards, in that two fire extinguishers were placed on the floor instead of being mounted on the walls. Employees can use the fire extinguishers to fight incipient fires.
Recent events (1)
  • — Z (O) $0

1910.305 B03 II

Other-than-serious 1 instance 21 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(b)(3)(ii):Pull and junction boxes used on systems rated over 600 volts, nominal, were not closed by suitable covers securely fastened in place:  a) Kitchen; On or about February 22, 2022 and at times prior, employer exposed employees to electrical hazards, in that electrical panels did not contain a panel door. Employees use the panel to turn power on and off to the kitchen and exterior.
Recent events (1)
  • — Z (O) $0

1910.305 C04

Other-than-serious 1 instance 21 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(c)(4):Faceplates for flush-mounted snap switches. Snap switches mounted in boxes did not have faceplates installed so as to completely cover the opening and seat against the finished surface:  a) Kitchen Area; On or about February 22, 2022 and at times prior, employees are exposed to electrical hazards, in that faceplates were installed on outlets and light switches located in the kitchen and the hallway leading to the kitchen.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345794960.