VERMILLION, SD —
OSHA Inspection: SHUR-CO, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SHUR-CO, LLC in 1212 NORTH NORBECK STREET, VERMILLION, SD 57069 (NAICS 314910). OSHA activity number 345872584.
Where did this inspection happen?
- Establishment
- SHUR-CO, LLC
- Site address
- 1212 NORTH NORBECK STREET
- City
- VERMILLION
- State
- SD
- ZIP
- 57069
- Mailing
- 1212 NORTH NORBECK STREET, VERMILLION, SD 57069
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 314910
- Employees
- 15
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $8287.00 · Current $4900.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance. This includes, but not limited to the following: A)A specific statement of the intended use of the procedure B)Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. C)Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them. D)Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures. (a) Shur-Co, LLC, Inc. at 1212 North Norbeck Street, Vermillion, SD 57069: On or about and at times prior to March 30, 2022, the employer did not establish a program consisting of specific energy control procedures to control hazardous energy exposure on multiple energy source pieces of equipment to include but not limited to the Stimpson Double Action Grommet Machine (serial number 48838012). This condition exposed multiple employees to crushing, amputation shock and air embolisms while maintaining equipment.
Recent events (2)
- — I (S) $4900
- — Z (S) $8287
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $14502.00 · Current $8700.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded or guards were not designed and constructed to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Shur-Co, LLC, Inc. at 1212 North Norbeck Street, Vermillion, SD 57069: On or about and at times prior to March 30, 2022, the employer did not ensure the point of operation on the Stimpson Double Action Grommet Machine (serial number 48838012) was properly guarded to prevent employees from having any part of the their body in the danger zone during machine operations. This hazard exposed employees to crushing and amputation hazards.
Recent events (2)
- — I (S) $8700
- — Z (S) $14502
1910.212 A03 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.212(a)(3)(iii): Special handtools were not used for placing and removing material to permit safe handling of material without the operator placing a hand in the danger zone. Such tools shall not be in lieu of other guarding required by this section, but can only be used to supplement protection provided: (a) Shur-Co, LLC, Inc. at 1212 North Norbeck Street, Vermillion, SD 57069: On or about and at times prior to March 30, 2022, the employer did not ensure that special tools or other means were utilized for placing and/or removing materials from the Stimpson Double Action Grommet Machine (serial number 48838012). This condition exposed the employee to amputation hazards associated with the punch and mandrel.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at SHUR-CO, LLC
DECATUR, IL—2021-05-21 00:00:00
SHUR-CO, LLC
View SHUR-CO, LLC's full OSHA safety record →
More inspections in this industry (NAICS 314910)
TAMAQUA, PA—2026-05-05
MAINSTREET MANUFACTURING COMPANY LLC
TAMAQUA, PA—2026-03-30
MAINSTREET MANUFACTURING COMPANY LLC
FORT LAUDERDALE, FL—2026-01-28
INDUSTRIAL SHADEPORTS, INC.
SPRING, TX—2026-01-22
AAA CANVAS & AWNING CO., INC.
ROMULUS, MI—2025-12-19
DETROIT TARPAULIN & REPAIR SHOP INC
More inspections in SD
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.