Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LA NORTENA TAMALE FACTORY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LA NORTENA TAMALE FACTORY in 211 EAST 3RD STREET, PECOS, TX 79772 (NAICS 311999). OSHA activity number 345930457.

Watch LA Nortena Tamale Factory — free Get an email when a new federal OSHA severe-injury report for LA Nortena Tamale Factory is published. One employer, no account, unsubscribe in one click.
Site address
211 EAST 3RD STREET
City
PECOS
State
TX
ZIP
79772
Mailing
211 EAST 3RD STREET, PECOS, TX 79772
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311999
Employees
10
Ownership type
A

6 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 4 instances 5 exposed
Issued
Abate by
Penalty
Initial $5801.00 · Current $3000.00 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   On or about April 28, 2022, employees were exposed to struck-by and entanglement hazards in the following instances:  (a) The 220V/3-Phase Hobart dough mixing bowl and auger was not guarded.  (b) The electric J.C. Ford corn grinder (240V/3-Phase, Model # CM30-16 / SS# CM 031105) was not guarded.  (c) The conveyor belt nip points and rotating shaft to the electric tamale making machine were not guarded, the machine was operated by a Dayton Industrial Motor (3450/2850 RPMs).  (d) The cutter to electric tamale machine was not guarded, the machine was operated by a Dayton Industrial Motor (3450/2850 RPMs).
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5801

1910.219 P06 II

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2486.00 · Current $1000.00 Reduced
29 CFR  1910.219(p)(6)(ii):Inspections were not made of belts, lacings, and fasteners and such equipment was not kept in good repair:  On or about April 28, 2022, the conveyor belt to the electric tamale machine was torn and brittle, the machine was operated by a Dayton Industrial Motor (Dayton Industrial Motor (3450/2850 RPMs).  This condition exposed employees to struck-by hazards.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2486

1910.303 B02

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4144.00 · Current $2000.00 Reduced
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  On or about April 28, 2022, at the dry storage area, an L620 C Turnlok Connector (20Amp/250V) was being used in place of a wall receptacle.  The inner connectors were fully exposed  and suspended from the receptacle opening in the wall. This condition exposed employees to electrocution, electrical shock and burn hazards.
Recent events (2)
  • — I (O) $2000
  • — Z (S) $4144

1910.305 B02 I

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4972.00 · Current $2500.00 Reduced
29 CFR  1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  On or about April 28, 2022, located on the wall and right above the tamale making machine, the faceplate of the 110V two outlet receptacle was detached from the wall and was exposing live electrical parts. This condition exposed employees to electrical shock and burn hazards.
Recent events (2)
  • — I (O) $2500
  • — Z (S) $4972

1910.305 C04

Other-than-serious Gravity 5 3 instances 4 exposed
Issued
Abate by
Penalty
Initial $3315.00 · Current $1500.00 Reduced
29 CFR  1910.305(c)(4): Snap switches mounted in boxes did not have faceplates installed so as to completely cover the opening and seat against the finished surface.  On or about April 28, 2022, employees were exposed to electrical shock and burn hazards in the following instances:   (a) In the cleaning storage area the three snap switch faceplate cover was broken and exposing live electrical parts.  (b) In the dry storage area the snap switch faceplate cover was broken and exposing live electrical parts.  (c)  The snap switch located in the back room just behind the retail store, was pushed inward beyond the metal faceplate and exposing live electrical parts.
Recent events (2)
  • — I (O) $1500
  • — Z (S) $3315

1904.33 A

Other-than-serious 5 instances 16 exposed
Issued
Abate by
Penalty
Initial $829.00 · Current $500.00 Reduced
29 CFR 1904.33(a): The employer did not maintain the OSHA 300 logs , the privacy case list, the annual summary  and the OSHA 301 Incident Report forms for the calendar year 2021.   On or about April 28, 2022, the employer did not maintain OSHA 300/300A logs for 2021.
Recent events (2)
  • — I (O) $500
  • — Z (O) $829

RNWBL