Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PR CONSTRUCTION, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PR CONSTRUCTION, LLC. in 1419 SPRING ROAD, WASHINGTON, DC 20010 (NAICS 238130). OSHA activity number 345964142.

Watch PR Construction, LLC. — free Get an email when a new federal OSHA severe-injury report for PR Construction, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
1419 SPRING ROAD
City
WASHINGTON
State
DC
ZIP
20010
Mailing
19226 WARRIOR BROOK DRIVE, GERMANTOWN, MD 20874
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

5 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 2 instances 2 exposed
Issued
Penalty
Initial $2735.00 · Current $2735.00
29 CFR  1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying objects:   a) Second Floor - Employee was using a Paselode pneumatic nail gun to attach 2 by 6 inch wood framing members and not wearing eye protection, on or about 05/17/2022.  b) Second Floor - Employee was using a Makita portable electric circular saw, model number 5007F, serial number 226583K, to cut wood framing members and not wearing eye protection, on or about 05/17/2022.  NO ABATEMENT DOCUMENTATION REQUIRED
Recent events (1)
  • — Z (S) $2735

1926.501 B13

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $5470.00 · Current $5470.00
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a) Second Floor - Employees working on an open deck while preparing the exterior wall panels were not wearing fall protection and were exposed to an approximate fall hazard of  9 feet 9 inches, on or about 05/17/2022.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $5470

1926.1053 B01

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $3646.00 · Current $3646.00
29 CFR  1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder:  a) Between First and Second Floors - Employees were using a 6 foot portable step ladder to gain access to an upper floor and the ladder was 3 foot, 9 inches short of the landing surface, on or about 05/17/2022.  NO ABATEMENT DOCUMENTATION REQUIRED
Recent events (1)
  • — Z (S) $3646

1926.1053 B04

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:  a) First Floor - Employees were using a 6 foot portable step ladder that was over 3 foot short of the landing surface and was not designed for that type of use, on or about 05/17/2022.  NO ABATMENT DOCUMENTATION REQUIRED
Recent events (1)
  • — Z (S) $0

1926.1053 B13

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.1053(b)(13): The top or top step of a stepladder was used as a step:  a) First Floor - Employees were standing on the top step of a 6 foot portable step ladder to gain access to the upper landing, on or about 05/17/2022.  NO ABATEMENT DOCUMENTATION REQUIRED
Recent events (1)
  • — Z (S) $0

View PR CONSTRUCTION, LLC.'s full OSHA safety record →