Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: LAMAR SCHROCK

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of LAMAR SCHROCK in 236 EAST COUNTY ROAD 575 NORTH, ARTHUR, IL 61911 (NAICS 337110). OSHA activity number 346016124.

Watch Lamar Schrock — free Get an email when a new federal OSHA severe-injury report for Lamar Schrock is published. One employer, no account, unsubscribe in one click.
Establishment
LAMAR SCHROCK
Site address
236 EAST COUNTY ROAD 575 NORTH
City
ARTHUR
State
IL
ZIP
61911
Mailing
236 EAST COUNTY ROAD 575 NORTH, ARTHUR, IL 61911
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
19
Ownership type
A

3 citations on file for this inspection.

1910.147 C07 I A

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $4144.00 · Current $2486.00 Reduced
29 CFR  1910.147(c)(7)(i)(A):  Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:  On or about June 9, 2022, an employee was exposed to amputation hazards while performing machine servicing operations on a Drawer Box Notcher, and the employer did not provide the employee with authorized employee lockout training.
Recent events (2)
  • — I (S) $2486.2
  • — Z (S) $4144

1910.147 D

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $4144.00 · Current $2486.00 Reduced
29 CFR  1910.147(d):The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):   On or about June 9, 2022, an employee was exposed to amputation hazards while performing machine servicing operations on a Drawer Box Notcher, and the employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements}.  As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
  • — I (S) $2486.2
  • — Z (S) $4144

1910.213 R03

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $5801.00 · Current $3481.00 Reduced
29 CFR  1910.213(r)(3):  The point of operation on combination or universal woodworking machines was not guarded:  On or about June 9, 2022, an employee was exposed to amputation hazards while utilizing a Drawer Box Notcher, and the employer did not have adequate point of operation guarding in place to prevent employee exposure to all tools associated with the machine.
Recent events (2)
  • — I (S) $3480.6
  • — Z (S) $5801