PASS CHRISTIAN, MS —
OSHA Inspection: ERICK MEJIA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ERICK MEJIA in 118 MENGE AVE., PASS CHRISTIAN, MS 39571 (NAICS 423330). OSHA activity number 346021140.
Where did this inspection happen?
- Establishment
- ERICK MEJIA
- Site address
- 118 MENGE AVE.
- City
- PASS CHRISTIAN
- State
- MS
- ZIP
- 39571
- Mailing
- 330 SUNNY DR, DIBERVILLE, MS 39540
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423330
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B01
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $4351.00
General-duty citation text
29 CFR 1926.501(b)(1):"Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. (a) South side of roof - On or about June 15, 2022 the employer instructed his employees to work on the roof with a 6/12 pitch, without the use of any fall protection system exposing employees to fall hazards.
Recent events (1)
- — Z (S) $4351
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. (a) South side of building- On or about June 15, 2022, the employee had employees use an aluminum extension ladder to gain access to the upper level that did not extend 3 feet past the upper level exposing them to fall hazards.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 423330)
SPOKANE VALLEY, WA—2026-07-15 00:00:00
WA317992075 - SRS DISTRIBUTION INC
ALBANY, NY—2026-07-13 00:00:00
GENERAL INSULATION COMPANY, INC.
KLAMATH FALLS, OR—2026-07-07 00:00:00
317744722 - NORTHWEST QUALITY ROOFING LLC
PORT ORCHARD, WA—2026-06-25 00:00:00
WA317991918 - CONVOY SUPPLY INC
ROSEVILLE, CA—2026-06-23 00:00:00
RWC BUILDING PRODUCTS - SACRAMENTO
More inspections in MS
LAUREL, MS—2026-07-01 00:00:00
THERMO-KOOL
HORN LAKE, MS—2026-07-01 00:00:00
NEWLY WEDS FOODS, INC.
GAUTIER, MS—2026-07-01 00:00:00
DOUBLE R GAUTIER, LLC
OLIVE BRANCH, MS—2026-06-30 00:00:00
HYVE SOLUTIONS
GAUTIER, MS—2026-06-30 00:00:00
STEVE WILSON ENTERPRISE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346021140.