Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MAYFIELD ENERGY, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MAYFIELD ENERGY, LLC in 10 MARSHALL LANE, ARANSAS PASS, TX 78336 (NAICS 211130). OSHA activity number 346137128.

Watch Mayfield Energy, LLC — free Get an email when a new federal OSHA severe-injury report for Mayfield Energy, LLC is published. One employer, no account, unsubscribe in one click.
Site address
10 MARSHALL LANE
City
ARANSAS PASS
State
TX
ZIP
78336
Mailing
3406 MULBERRY CREEK DRIVE, AUSTIN, TX 78732
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
211130
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.352 I

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $4351.00 · Current $4351.00
29 CFR  1926.352(i): Drums containers, or hollow structures which have contained toxic or flammable substances were not, before welding, cutting, or heating was undertaken on them, either be filled with water or thoroughly cleaned of such substances and ventilated and tested.   On or about August 4, 2022 at this work place, employees conducted welding and cutting operations on a petroleum tank/vessel door sheet,  the vessel was not filled with water, nor was it cleaned, ventilated or tested adequately to prevent flammable substances from ignition and exploding.
Recent events (2)
  • — C (S) $4351
  • — Z (S) $4351

1926.352 J

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $4351.00 · Current $4351.00
29 CFR  1926.352(j): Before heat is applied to a drum, container, or hollow structure, a vent or opening was not provided for the release of any built-up pressure during the application of heat.   On or about August 4, 2022 at this work place, employees conducted welding and cutting operations on a petroleum tank/vessel door sheet,  the door sheet was not removed from the tank/vessel opening to provide for the release of any build-up pressure during the application of heat.
Recent events (2)
  • — C (S) $4351
  • — Z (S) $4351

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346137128.