1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: FIRST SERVICE CGC, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FIRST SERVICE CGC, INC. in 13545 EAGLE RIDGE DR, FORT MYERS, FL 33912 (NAICS 238160). OSHA activity number 346141971.

Watch First Service CGC, INC. — free Get an email when a new federal OSHA severe-injury report for First Service CGC, INC. is published. One employer, no account, unsubscribe in one click.
Site address
13545 EAGLE RIDGE DR
City
FORT MYERS
State
FL
ZIP
33912
Mailing
1364 TOUCHSTONE ROAD, FORT MYERS, FL 33903
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
35
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $10151.00 · Current $6091.00 Reduced
29 CFR  1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a.) On or about August 12, 2022, at the clubhouse,  employees in the process of installing tiles on the roof and conducting cleaning activities  on a  6 in 12 slope (vertical to horizontal) roof, were exposed to fall hazards up to 9'5", in that, fall protection equipment was not installed or utilized.
Recent events (2)
  • — I (S) $6090.6
  • — Z (S) $10151

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $7252.00 · Current $4351.00 Reduced
29 CFR  1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder.     a.) On or about August 12, 2022, at the club house, employees were exposed to a 9ft 5 in. fall hazards in that, the  ladder's side rails were not extended at least 3 feet above the upper landing surface and the ladder was not secured to the building.
Recent events (2)
  • — I (S) $4351.2
  • — Z (S) $7252

1926.1053 B08

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder.   a.) On or about August 12, 2022, at the club house, employees were exposed to a 9ft 5 in. fall hazards in that, the  ladder was set up near the doorway which could cause displacement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View FIRST SERVICE CGC, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346141971.