SAN ANTONIO, TX —
OSHA Inspection: CHAIN ELECTRIC COMPANY, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CHAIN ELECTRIC COMPANY, INC. in 6416 GRISSOM RD (FREEDOM CHURCH-HIGHWAY EASEMENT), SAN ANTONIO, TX 78238 (NAICS 238210). OSHA activity number 346161987.
Where did this inspection happen?
- Establishment
- CHAIN ELECTRIC COMPANY, INC.
- Site address
- 6416 GRISSOM RD (FREEDOM CHURCH-HIGHWAY EASEMENT)
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78238
- Mailing
- 1308 WEST PINE ST., HATTIESBURG, MS 39401
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 120
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.251 D02
- Issued
- Abate by
- Penalty
- Initial $15625.00 · Current $15000.00 Reduced
General-duty citation text
29 CFR 1926.251(d)(2): All splices in rope slings provided by the employer were not made in accordance with fiber rope manufacturers recommendations: 6416 Grissom Road, San Antonio, TX: On or about August 18, 2022, and times prior thereto, employees were exposed to struck by hazards while using synthetic winch line with a splice that had not been made according to manufacturer's recommendations.
Recent events (3)
- — C (S) $15625
- — F (O) $15000
- — Z (S) $15625
1926.959 A02
- Issued
- Abate by
- Penalty
- Initial $15625.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.959(a)(2): Inspection before use. The critical safety components of mechanical elevating and rotating equipment did not receive a thorough visual inspection before use on each shift. (a) 6416 Grissom Road, San Antonio, TX: On or about August 18, 2022, and times prior thereto, employees were exposed to struck by hazards while performing pole installation work with a digger derrick that had not been inspected for critical inspections, to include Hydraulic Overload Protection (HOP) inspections, in accordance with manufacturer's requirements. (b) 6416 Grissom Road, San Antonio, TX: On or about August 18, 2022, and times prior thereto, employees were exposed to struck by hazards performing pole installation work with a digger derrick that had not been inspected, including its safety devices, on a monthly and daily basis, in accordance with manufacturer's requirements.
Recent events (3)
- — C (S) $15625
- — F (O) $0
- — Z (S) $15625
More inspections at CHAIN ELECTRIC COMPANY, INC.
SAN ANTONIO, TX—2017-10-26 00:00:00
CHAIN ELECTRIC COMPANY, INC.
ENTERPRISE, MS—2017-08-17 00:00:00
CHAIN ELECTRIC COMPANY, INC.
DAPHNE, AL—2015-06-19 00:00:00
CHAIN ELECTRIC COMPANY, INC.
View CHAIN ELECTRIC COMPANY, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238210)
SOUTH FULTON, GA—2026-07-10
REEDWICK, LLC
NIAGARA FALLS, NY—2026-07-10
GAINES ELECTRICAL CONTRACTING, INC.
OGDENSBURG, NY—2026-07-10
S & L ELECTRIC, INC.
BOISE, ID—2026-07-09
POWERHOUSE ELECTRIC INC.
LYNCHBURG, VA—2026-07-09
WHITE ELECTRICAL SERVICES LLC
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346161987.