MARINETTE, WI —
OSHA Inspection: MC MANUFACTURING LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MC MANUFACTURING LLC in W2874 WISCONSIN 64, MARINETTE, WI 54143 (NAICS 331511). OSHA activity number 346231954.
Where did this inspection happen?
- Establishment
- MC MANUFACTURING LLC
- Site address
- W2874 WISCONSIN 64
- City
- MARINETTE
- State
- WI
- ZIP
- 54143
- Mailing
- W2874 WISCONSIN 64, MARINETTE, WI 54143
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331511
- Employees
- 11
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.178 L01 I
- Issued
- Penalty
- Initial $4465.00 · Current $2233.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). On or about September 19, 2022, at the facility located at W2874 Highway 64, Marinette, Wisconsin, the employer failed to ensure each powered industrial truck operator is competent as demonstrated by completion of a driving evaluation.
Recent events (2)
- — I (S) $2232.5
- — Z (S) $4465
1910.305 B02 I
- Issued
- Penalty
- Initial $4465.00 · Current $2233.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear. On or about September 19, 2022, at the facility located at W2874 Highway 64, Marinette, Wisconsin, the employer exposed employees to contact with electrical current by failing to ensure the Campbell Hausfeld air compressor (Model No.: SS5106V, Serial No.: 030685L-180402) junction box cover was properly installed.
Recent events (2)
- — I (S) $2232.5
- — Z (S) $4465
1910.305 G01 IV
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used: As a substitute for the fixed wiring of a structure. On or about September 19, 2022, at the facility located at W2874 Highway 64, Marinette, Wisconsin, the employer allowed flexible cords to be used as a substitute for fixed wiring. a. An extension cord was used to supply power to the computer used at the CNC Machining Center. b. An extension cord was used to power a light fixture at the workbench for the Mitsubishi 3015 LVPlus Laser.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 331511)
CORSICANA, TX—2026-07-01 00:00:00
OIL CITY IRON WORKS, INC.
CORNWALL, PA—2026-07-01 00:00:00
PRL INDUSTRIES INC
CORNWALL, PA—2026-07-01 00:00:00
PRL INDUSTRIES INC
EASTON, PA—2026-07-01 00:00:00
VICTAULIC COMPANY
HAMBURG, PA—2026-06-18 00:00:00
HAMBURG PLOW WORKS, INC.
More inspections in WI
WAUSAU, WI—2026-07-16 00:00:00
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15 00:00:00
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15 00:00:00
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15 00:00:00
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15 00:00:00
A. GOMEZ CARPENTRY, INC
Source