DEDEDO, GU —
OSHA Inspection: GUAM BAKERY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GUAM BAKERY in 140 KAYEN CHANDO, DEDEDO, GU 96929 (NAICS 311811). OSHA activity number 346300247.
Where did this inspection happen?
- Establishment
- GUAM BAKERY
- Site address
- 140 KAYEN CHANDO
- City
- DEDEDO
- State
- GU
- ZIP
- 96929
- Mailing
- 140 KAYEN CHANDO, DEDEDO, GU 96929
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311811
- Employees
- 7
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $8701.00 · Current $8701.00
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: A) Cake Decorating Room: The Chanmag mixer's rotating shafts and blades were not guarded. Employees were exposed to the rotating part hazards. B) Production area: The large Hobart mixer's rotating shafts and blades were not guarded. Employees were exposed to the rotating part hazards. C) Production area: The small Hobart mixer's rotating shafts and blades were not guarded. Employees were exposed to the rotating part hazards. The Guam Bakery was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1414433, citation number 1, item number 1 and was affirmed as a final order on 10/17/2019, with respect to a workplace located at 140 Kayen Chando, Dededo, Guam, 96929.
Recent events (1)
- — Z (R) $8701
1910.215 A04
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $4351.00
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: Delta Machinery bench grinder: The adjustable work rest guard was missing, creating an opening greater than one eighth of an inch. Employees were exposed to laceration hazards and flying particle hazards.
Recent events (1)
- — Z (S) $4351
1910.215 B09
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: Delta Machinery bench grinder: The adjustable tongue guard was missing, creating an opening greater than one fourth inch. Employees were exposed to laceration hazards and flying particle hazards.
Recent events (1)
- — Z (S) $0
1910.37 B06
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color: In the loading dock area: The emergency exit was labeled with a paper non-luminescent exit sign. Employees were exposed to egress impediments.
Recent events (1)
- — Z (O) $0
1910.157 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: A) Inside the entry to kitchen from the retail space: The ABC fire extinguisher was not mounted. Employees were exposed to fire hazards such as smoke inhalation and burns. B) In the loading dock area: The ABC fire extinguisher was blocked by storage and large pallets. Employees were exposed to struck-by hazards while removing the fire extinguisher from its location and fire hazards such as smoke inhalation and burns.
Recent events (1)
- — Z (O) $0
1910.303 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: A) Washing Area: Electrical panel 7 was blocked by steamer racks. Access was restricted in the event of an emergency. B) Right of the loading dock door: Electrical panel was blocked by bags of old bread. Access was restricted in the event of an emergency. C) Behind the Svebadahlen steam oven: Electrical panel 6 was blocked by baking racks and a trach can. Access was restricted in the event of an emergency. D) Mixing area for bread: Electrical panel was blocked by cake flour ingredient bins. Access was restricted in the event of an emergency.
Recent events (1)
- — Z (O) $0
1910.305 A02 IX
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(a)(2)(ix): Lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard: Inside the women's restroom: A light fixture was not protected with an appropriate cover. Employees were exposed to laceration and electrical hazards.
Recent events (1)
- — Z (O) $0
More inspections at GUAM BAKERY
DEDEDO, GU—2019-07-11 00:00:00
GUAM BAKERY
View GUAM BAKERY's full OSHA safety record →
More inspections in this industry (NAICS 311811)
LAKELAND, FL—2026-07-09
PUBLIX BAKERY PLANT
ARLINGTON, WA—2026-07-09
WA317991969 - HAMMOND BREAD COMPANY LLC
VIRGINIA, MN—2026-06-24
111466 - GRUTZ CORP DBA PEPS BAKE SHOP
HELENA, MT—2026-06-17
VANILLA BEAN BAKERY, LLC
VANCOUVER, WA—2026-06-17
WA317991733 - WINPIN 85 INVESTMENTS LLC
More inspections in GU
BARRIGADA, GU—2026-01-22
DURI CORPORATION
TAMUNING, GU—2026-01-21
DLR CORPORATION
BARRIGADA, GU—2026-01-21
DURI CORPORATION
TAMUNING, GU—2026-01-20
MG CONSTRUCTION COMPANY
BARRIGADA, GU—2026-01-20
PFM -VERTEX-LMS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346300247.