Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DURA-TECH PROCESSES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DURA-TECH PROCESSES, INC. in 1204 ANTLER DR., MANSFIELD, TX 76063 (NAICS 332813). OSHA activity number 346300882.

Watch Dura-Tech Processes, INC. — free Get an email when a new federal OSHA severe-injury report for Dura-Tech Processes, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1204 ANTLER DR.
City
MANSFIELD
State
TX
ZIP
76063
Mailing
109 CENTRY DR., MANSFIELD, TX 76063
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
40
Ownership type
A

3 citations on file for this inspection.

1910.29 F04

Serious Gravity 1 3 instances 6 exposed
Issued
Abate by
Penalty
Initial $4351.00 · Current $2611.00 Reduced
29 CFR 1910.29(f)(4): Openings in stair rails. The employer did not ensure that no opening in a stair rail system exceeds 19 inches (48 cm) at its least dimension.  On or about October 24, 2022, and times prior thereto, the employer did not installed standard rails such as mid-rails on stairs utilized to access upper landings to conduct work in and around tanks exposing employees to fall hazards.  a) At the northeast side of the storage tanks, employees access tanks using a stairway missing mid-rails,  b) At the southeast side of the storage tanks, employees access tanks using a stairway missing mid-rails,  c) In the waste treatment department, employees access tanks using a stairway missing mid-rails.
Recent events (2)
  • — I (S) $2610.6
  • — Z (S) $4351

1910.157 C01

Serious Gravity 1 3 instances 6 exposed
Issued
Penalty
Initial $3698.00 · Current $2219.00 Reduced
29 CFR  1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries.  On or about October 24, 2022, and times prior thereto, the employer did not ensure fire extinguishers were identified with a fire extinguisher sign and ready accessible for employees exposing to fire and smoke hazards.  a) At the northeast exit door, fire extinguisher sign missing above fire extinguisher,  b) At the southwest exit door, fire extinguisher sign missing above fire extinguisher.
Recent events (2)
  • — I (S) $2218.8
  • — Z (S) $3698

1910.305 G01 IV A

Other-than-serious 3 instances 6 exposed
Issued
Penalty
Initial $692.00 · Current $415.00 Reduced
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.  On or about October 24, 2022, and times prior thereto, an extension cord, wrapped tied around a metal storage, was used as permanent wiring to energize an Optima digital weight scale, exposing employees to electrical shock hazards.
Recent events (2)
  • — I (O) $415.2
  • — Z (O) $692

View DURA-TECH PROCESSES, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346300882.