Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DURA-TECH PROCESSES, INC.

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of DURA-TECH PROCESSES, INC. in 1204 ANTLER DR., MANSFIELD, TX 76063 (NAICS 332813). OSHA activity number 347114001.

Watch Dura-Tech Processes, INC. — free Get an email when a new federal OSHA severe-injury report for Dura-Tech Processes, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1204 ANTLER DR.
City
MANSFIELD
State
TX
ZIP
76063
Mailing
109 CENTRY DR., MANSFIELD, TX 76063
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
40
Ownership type
A

3 citations on file for this inspection.

1910.157 C01

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $746.00 · Current $448.00 Reduced
29 CFR  1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries.  On or about November 17, 2023, and at times prior thereto, west side of the warehouse, the employer did not ensure employees had clear access to the fire extinguisher exposing employees to fire and smoke hazards.
Recent events (2)
  • — I (O) $447.6
  • — Z (O) $746

1910.303 B01 IV

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $746.00 · Current $448.00 Reduced
29 CFR  1910.303(b)(1)(iv):Electric equipment was not free from recognized hazards that were likely to cause serious physical harm to employees, such as damaged electrical insulation:  On or about November 17, 2023, and at times prior thereto, north side of the warehouse, the employees were exposed to electrical injuries due to an electrical junction box missing the cover plate.
Recent events (2)
  • — I (O) $447.6
  • — Z (O) $746

1910.305 B03 II

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(b)(3)(ii): 29 CFR  1910.305(b)(3)(ii): Boxes were not closed by a suitable cover and securely fastened in place.   On or about November 17, 2023, and at times prior thereto, west side of the warehouse, an electrical panel box that energizes lights and machines was left open exposing employees to electrical shock hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View DURA-TECH PROCESSES, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347114001.