Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: LA MICHOCANA

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of LA MICHOCANA in 3040 LITTLE YORK ROAD, HOUSTON, TX 77093 (NAICS 445210). OSHA activity number 346401961.

Watch LA Michocana — free Get an email when a new federal OSHA severe-injury report for LA Michocana is published. One employer, no account, unsubscribe in one click.
Establishment
LA MICHOCANA
Site address
3040 LITTLE YORK ROAD
City
HOUSTON
State
TX
ZIP
77093
Mailing
3040 LITTLE YORK ROAD, HOUSTON, TX 77093
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
445210
Employees
21
Ownership type
A

4 citations on file for this inspection.

1910.22 A01

Other-than-serious Gravity 5 1 instance 20 exposed
Issued
Penalty
Initial $3572.00 · Current $2858.00 Reduced
29 CFR  1910.22(a)(1):  The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition.   On or about December 20, 2022,  in the back hallway storage area,  the employer did not ensure that all stacked merchandise within the hallway was stable and secure against sliding and collapse.
Recent events (2)
  • — I (O) $2857.6
  • — Z (S) $3572

1910.304 F01 IV

Other-than-serious Gravity 10 1 instance 21 exposed
Issued
Penalty
Initial $6250.00 · Current $5000.00 Reduced
29 CFR  1910.304(f)(1)(iv):Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel:  On or about December 20, 2022, in the back hallway storage area,  electrical panels containing overcurrent devices were not readily accessible due to being blocked by boxed food, various merchandise and cleaning equipment .
Recent events (2)
  • — I (O) $5000
  • — Z (S) $6250

1910.305 B01 II

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2678.00 · Current $2142.00 Reduced
29 CFR  1910.305(b)(1)(ii):Unused openings in boxes, cabinets, or fittings were not effectively closed:  On or about December 20, 2022,  in the back hall way storage area, in breaker panel number 1,  breaker number 41,  where employees are exposed to  electrical hazard(s) when accessing the breaker panel without blanks being installed where there are unused openings.
Recent events (2)
  • — I (O) $2142.4
  • — Z (S) $2678

1910.305 B02 I

Other-than-serious Gravity 5 2 instances 21 exposed
Issued
Abate by
Penalty
Initial $3572.00 · Current $2858.00 Reduced
29 CFR  1910.305(b)(2)(i):Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  a. On or about December 20, 2022, in back hall way storage area, employees were exposed to electrical hazards when working near an unprotected electrical outlet.    b. On or about December 20, 2022, in the back hall way storage area,  employees were exposed to electrical hazards when working near an unprotected electrical panel box.
Recent events (2)
  • — I (O) $2857.6
  • — Z (S) $3572

RNWBL