COLORADO SPRINGS, CO —
OSHA Inspection: XCITE MANUFACTURING, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of XCITE MANUFACTURING, LLC in 1080 FORD STREET, COLORADO SPRINGS, CO 80915 (NAICS 332312). OSHA activity number 346599111.
Where did this inspection happen?
- Establishment
- XCITE MANUFACTURING, LLC
- Site address
- 1080 FORD STREET
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80915
- Mailing
- 1080 FORD STREET, COLORADO SPRINGS, CO 80915
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 16
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.95 C01
- Issued
- Abate by
- Penalty
- Initial $5358.00 · Current $3215.00 Reduced
8111
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: (a) 1080 Ford Street, Colorado Springs, CO 80915: On or about April 12, 2023, and at times prior, the employer did not implement an effective hearing conservation program when employee noise exposures equaled or exceeded 85 decibels measured on the A scale.
Recent events (2)
- — I (S) $3214.8
- — Z (S) $5358
1910.95 D01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
8111
General-duty citation text
29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program: (a) 1080 Ford Street, Colorado Springs, CO 80915: On or about April 12, 2023, and at times prior, the employer did not implement a monitoring program when information indicated that an employee's exposure to hazardous noise met or exceeded 85 decibels.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.95 G01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
8111
General-duty citation text
29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels: (a) 1080 Ford Street, Colorado Springs, CO 80915: On or about April 12, 2023, and at times prior, the employer did not develop and maintain an audiometric testing program or make audiometric testing available to employees when employee noise exposures equaled or exceeded 85 decibels measured on the A scale (dBA).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 A01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition: (a) 1080 Ford Street, Colorado Springs, CO 80915: On or about April 12, 2023, and at times prior, the employer did not ensure that all places of employment were kept in a clean, orderly, and sanitary condition. An unsecured air hose was observed laying across an employee walkway behind the band saw in the extrusion area next to the East wall.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.242 B
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: (a) 1080 Ford Street, Colorado Springs, CO 80915: On or about April 12, 2023, and at times prior, compressed air used for cleaning purposes was set to 125 p.s.i. on the WS Controller air compressor. Employees use compressed air to clean aluminum debris from the stretching machines and other machine parts.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) 1080 Ford Street, Colorado Springs, CO 80915: On or about April 12, 2023, and at times prior, the employer did not ensure that sufficient access and working space was provided and maintained around electrical equipment. An electrical panel on the northeast corner of the building was blocked by a piece of equipment.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 332312)
WYOMING, MI—2026-07-16 00:00:00
R&M FABRICATION LLC
TRUSSVILLE, AL—2026-07-16 00:00:00
ALL SOUTH STEELWORX, LLC
NORTH BRANCH, MN—2026-07-15 00:00:00
111603 - BROWN HAWK LLC DBA NORTHERN LIGHTS STEEL FAB
VAN BUREN, AR—2026-07-14 00:00:00
MILLAR PARTNERS, LLC
CLANTON, AL—2026-07-14 00:00:00
C & S CANOPY, INC.
More inspections in CO
BROOMFIELD, CO—2026-07-16 00:00:00
WAVELYNX TECHNOLOGIES LLC
COLORADO SPRINGS, CO—2026-07-15 00:00:00
ELMER CONTRACTOR LLC
SHERIDAN, CO—2026-07-15 00:00:00
JOHN'S COLLISION REPAIR, INC.
CENTENNIAL, CO—2026-07-15 00:00:00
BRAKES PLUS, INC
ENGLEWOOD, CO—2026-07-15 00:00:00
PCL CIVIL CONSTRUCTORS INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346599111.