PITTSFIELD, MA —
OSHA Inspection: ERICKS CONSTRUCTION INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ERICKS CONSTRUCTION INC in 12 JOSEPH DR., PITTSFIELD, MA 01201 (NAICS 238160). OSHA activity number 346613474.
Where did this inspection happen?
- Establishment
- ERICKS CONSTRUCTION INC
- Site address
- 12 JOSEPH DR.
- City
- PITTSFIELD
- State
- MA
- ZIP
- 01201
- Mailing
- 9 OAKLAND PLACE UNIT 9, BROCKTON, MA 02301
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $4688.00 · Current $2344.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1):The employer did not ensure that each affected employee use appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors or potentially injurious light radiation. 12 Joseph Drive Pittsfield, MA 01201: On or about April 4, 2023, an employee was seen without eye protection while using a pneumatic nail gun to shingle a roof and the employer did not ensure the employee use appropriate eye protection.
Recent events (2)
- — I (S) $2344
- — Z (S) $4688
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $4688.00 · Current $2344.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): 12 Joseph Drive Pittsfield, MA 01201: On or about April 4, 2023, three employees were exposed to fall hazards of approximately 8 feet 7 inches above a lower level while performing residential construction work and were not protected from falling by guard rail systems, safety net systems or a personal fall arrest system.
Recent events (2)
- — I (S) $2344
- — Z (S) $4688
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $4688.00 · Current $2344.00 Reduced
General-duty citation text
29 CFR 1926.503(a)(1):The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards 12 Joseph Drive Pittsfield, MA 01201: On or about April 4, 2023, the employer had not trained an employee, who was exposed to fall hazards of approximately 8 feet 7 inches while performing residential roofing work, to recognize fall hazards and on the procedures to be followed to minimize these hazards.
Recent events (2)
- — I (S) $2344
- — Z (S) $4688
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $3349.00 · Current $1675.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: 12 Joseph Drive Pittsfield, MA 01201: On or about April 4, 2023, the employer did not ensure that employees using ladders to access an upper surface (roof) approximately 8 feet 7 inches above the ground had the rails extended at least 3 feet above the upper landing.
Recent events (2)
- — I (S) $1674.5
- — Z (S) $3349
1926.1053 B04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(4):Ladder(s) were used for purposes other than the purpose for which they were designed: 12 Joseph Drive Pittsfield, MA 01201: On or about April 4, 2023, the employer had not ensured that ladders being used to access a residential roof were used only for the purposes they were designed as an employee used a laddervator (shingle lift) extension component to access the roof.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238160)
PORTLAND, OR—2026-07-17 00:00:00
317744797 - JBC ROOFING LLC
MERIDIAN, ID—2026-07-17 00:00:00
COBRA'S ROOFING LLC
SYRACUSE, NY—2026-07-17 00:00:00
NAMICELA HOME SOLUTIONS INC
BRADLEY, IL—2026-07-16 00:00:00
JUAN CRUZ DBA ROOFBOYS LLC
PONCE INLET, FL—2026-07-16 00:00:00
RESOLUTE ROOFING LLC
More inspections in MA
WESTFORD, MA—2026-07-17 00:00:00
M&M CONSTRUCTION SERVICES CORP
ATTLEBORO, MA—2026-07-16 00:00:00
R M PACELLA INC
LYNN, MA—2026-07-16 00:00:00
A.M.B. IRON LLC
NEWTON, MA—2026-07-16 00:00:00
A&S CARPENTRY, INC.
BELLINGHAM, MA—2026-07-16 00:00:00
BELLINGHAM DEPARTMENT OF PUBLIC WORKS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346613474.