Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: PETER E REID STEVEDORING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PETER E REID STEVEDORING, INC. in FAGATAGA VILLAGE MAIN DOCK, PAGO PAGO, AS 96799 (NAICS 484220). OSHA activity number 346635428.

Watch Peter E Reid Stevedoring, INC. — free Get an email when a new federal OSHA severe-injury report for Peter E Reid Stevedoring, INC. is published. One employer, no account, unsubscribe in one click.
Site address
FAGATAGA VILLAGE MAIN DOCK
City
PAGO PAGO
State
AS
ZIP
96799
Mailing
PO BOX 1030, PAGO PAGO, AS 96799
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484220
Employees
40
Ownership type
A

8 citations on file for this inspection.

1917.43 C05

Serious Gravity 5 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $6641.00 · Current $4649.00 Reduced
29 CFR  1917.43(c)(5): Powered industrial trucks were not maintained in safe working order.  A. The Caterpillar Forklift with license plate C705 did not have a functional horn. Employees were exposed to crushed by and struck by hazards.   B. The Mitsubishi Caterpillar Forklift with license plate C717 did not have a functional horn and was not equipped with a functional operator restraint system. Employees were exposed to crushed by and struck by hazards.   C. The Taylor Machine Works Forklift Model THDC-954 was not equipped with a functional operator restraint system. Employees were exposed to crushed by and struck by hazards.
Recent events (2)
  • — I (S) $4648.7
  • — Z (S) $6641

1917.151 B01

Serious Gravity 1 2 instances 9 exposed
Issued
Abate by
Penalty
Initial $3984.00 · Current $2789.00 Reduced
29 CFR  1917.151(b)(1): Danger zones on machines and equipment used by employees were not guarded.  A) In the maintenance shop: The Precision Drilling Machine drill press used by employees for part repair and fabrication was not equipped with a chuck guard. Employees were exposed to rotating part hazards.  B) In the maintenance shop: The lathe used by an employee for part repair and fabrication was not equipped with a chuck guard. An employee was exposed to rotating part hazards.
Recent events (2)
  • — I (S) $2788.8
  • — Z (S) $3984

1910.157 C01

Other-than-serious 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  Maintenance Shop:  Four 55-gallon drums containing diesel fuel and motor oil blocked the available fire extinguisher so that it was not readily accessible without moving the nearly full drums.  Employees were exposed to crush-by injuries from the drums and fire hazards such as smoke inhalation and burns.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B02

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Front office area, by Site Supervisor's Desk: Two relocatable power taps (RPTs) and an extension cord were connected in-series (daisy chained) that provided power to the radios and their chargers. Employees were exposed to fire and electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 3 instances 9 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  A) Maintenance Shop: Access to the emergency shut-off for the lathe machine was blocked by the machine itself and a worktable set up next to it.  Employees were exposed to electrical hazards.  B) Maintenance Shop: Access to the breaker box for the air compressor was blocked by a worktable.  Employees were exposed to electrical hazards.  C) Tire Repair Room: Access to the Main Breaker was blocked with tire rims.  Employees were exposed to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B01 I

Other-than-serious 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasion, and openings through which conductors enter were not effectively closed.   Maintenance Shop, near door to Maintenance Manager's office: A conductor entering the junction box was exposed and not covered with conduit.  Employees were exposed to electrical  hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 J01 I

Other-than-serious 4 instances 11 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located had live parts normally exposed to employee contact:  A) Front office, behind Site Supervisor's desk: An outlet powering computer equipment did not have a cover. Employees were exposed to electrical hazards.  B) Front office, below minimum wage poster, near mounted fire extinguisher: An outlet did not have a cover. Employees were exposed to electrical hazards.  C) Front desk, behind Front Clerk's workstation: An outlet did not have a cover. Employees were exposed to electrical hazards.  D) Maintenance Shop, above electrical panel near door to Maintenance Manager's office: A junction box did not have a cover and there were live wires exposed.  Employees were exposed to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1917.152 D01 VII

Other-than-serious 2 instances 9 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1917.152(d)(1)(vii): Compressed gas cylinders were not secured in an upright position except when hoisted or carried.  A) Maintenance Shop, near entrance to restricted area: Two oxygen gas cylinders were unsecured near the fenced area of the restricted area.  Employees were exposed to struck-by hazards.  B) Maintenance Shop, behind door to Maintenance Shop from outside: One acetylene cylinder was unsecured.  Employees were exposed struck-by hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View PETER E REID STEVEDORING, INC.'s full OSHA safety record →

NNT INC.

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346635428.