OSHA Inspection: DOYLE'S ELECTRIC, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DOYLE'S ELECTRIC, INC. in 19045 NORTH MORRISON, HAMMOND, LA 70401 (NAICS 238210). OSHA activity number 346690043.

Watch Doyle'S Electric, INC. — free Get an email when a new federal OSHA severe-injury report for Doyle'S Electric, INC. is published. One employer, no account, unsubscribe in one click.
Site address
19045 NORTH MORRISON
City
HAMMOND
State
LA
ZIP
70401
Mailing
15035 JEFFERSON HWY, BATON ROUGE, LA 70812
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
3
Ownership type
A

5 citations on file for this inspection.

1926.651 C01 I

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $4687.00 · Current $0.00 Reduced
29 CFR  1926.651(c)(1)(i): Structural ramps that were used solely by employees as a means of access or egress from excavations were not designed by a competent person.   On or about May 10, 2023, employees were installing a line in excavation 4 feet or more in-depth using a ramp for access or egress not designed by a competent person qualified in structural design.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4687

1926.651 C01 V

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $4687.00 · Current $4687.00
29 CFR  1926.651(c)(1)(v): Structural ramps used in lieu of steps were not provided with cleats or other surface treatments on the top surface to prevent slipping.  On or about May 10, 2023, employees were installing a PVC feeder line in excavation 4 feet or more in-depth using a ramp for access or egress not designed by a competent person qualified in structural design and did not have cleating or other surface treatment to prevent the employees from slipping.
Recent events (2)
  • — I (O) $4687
  • — Z (S) $4687

1926.651 C02

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $4687.00 · Current $0.00 Reduced
29 CFR  1926.651(c)(2): A stairway, ladder, ramp, or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in-depth so as to require no more than 25 feet (7.62m) of lateral travel for employees.  On or about May 10, 2023, employees installed utility lines in an excavation four (4) feet or more in-depth without a safe means of egress.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4687

1926.651 J02

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $7813.00 · Current $7813.00
29 CFR  1926.651(j)(2): Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations, or by a combination of both if necessary.  On or about May 10, 2023, employees installed a PVC feeder where the spoils were not two feet from the edge of the excavation.
Recent events (2)
  • — I (S) $7813
  • — Z (S) $7813

1926.652 A01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $7813.00 · Current $0.00 Reduced
29 CFR  1926.652(a)(1):Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c).  On or about May 10, 2023, employees were in an excavation installing a PVC feeder lines in an excavation greater than five feet in depth that was not protected from cave-ins by an adequate protective system.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7813

View DOYLE'S ELECTRIC, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346690043.