ELGIN, IL —
OSHA Inspection: GULFSIDE SUPPLY, INC. DBA GULFEAGLE SUPPLY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GULFSIDE SUPPLY, INC. DBA GULFEAGLE SUPPLY in 375 RENNER DRIVE, ELGIN, IL 60123 (NAICS 423330). OSHA activity number 346695067.
Where did this inspection happen?
- Establishment
- GULFSIDE SUPPLY, INC. DBA GULFEAGLE SUPPLY
- Site address
- 375 RENNER DRIVE
- City
- ELGIN
- State
- IL
- ZIP
- 60123
- Mailing
- 2900 EAST 7TH AVE, TAMPA, FL 33605
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423330
- Employees
- 3
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.28 B01 I
- Issued
- Abate by
- Penalty
- Initial $8929.00 · Current $6250.00 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i):29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i): On or about May 30th, 2023, an employee was exposed to a fall hazard greater than 4 feet during the dismantling of the warehouse racking system. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $6250
- — Z (S) $8929
1910.178 L01 I
- Issued
- Abate by
- Penalty
- Initial $11162.00 · Current $5581.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i):The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). On or about May 11th, 2023, employees were exposed to struck-by or tip-over hazards. Two operators operated a Yale propane forklift prior to completing an evaluation of their performance. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (O) $5581
- — Z (S) $11162
1910.178 P01
- Issued
- Abate by
- Penalty
- Initial $8929.00 · Current $6250.00 Reduced
General-duty citation text
29 CFR 1910.178(p)(1):Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s). On or about May 11th, 2023, two employees were exposed to struck-by or crushing hazards during the operation of a Yale propane forklift with a non-functional horn and broken seatbelt mechanism housing. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $6250
- — Z (S) $8929
1910.36 D01
- Issued
- Abate by
- Penalty
- Initial $55810.00 · Current $36919.00 Reduced
General-duty citation text
29 CFR 1910.36(d)(1):Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge. On or about May 11th, 2023, the following exit doors were welded shut or otherwise inoperable, exposing employees to potential fire hazards: a) Warehouse, southwest loading dock door, equipped with illuminated "EXIT" sign - barricaded with steel brackets and non-removable lumber. b) Warehouse, south building door, equipped with illuminated "EXIT" sign and inoperable panic bar / alarm - welded at bottom with steel bracket. c) Warehouse, east side door, equipped with illuminated "EXIT" sign. Inoperable door and locking mechanism. d) Warehouse, north central building door, equipped with illuminated "EXIT" sign. Inoperable door and locking mechanism. e) Office coordinator to warehouse, north service door - inoperable, No form of exit demarcations. f) Vent room door - inoperable, welded from the outside. No form of exit demarcations. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d). Gulfside Supply, Inc. dba Gulfeagle Supply was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.36(d)(1), which was contained in OSHA Inspection number 1635443, Citation 1, Item number 1a and was affirmed as a final order on April 18, 2023, with respect to a workplace located at 1820 N. Central Avenue, Chicago, Illinois 60639.
Recent events (2)
- — I (R) $36919
- — Z (R) $55810
1910.37 A03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: On or about May 11th, 2023, the egress routes of the following exit routes were obstructed, exposing employees to potential fire hazards: a) Vent room door, discharges to outside lay down area, obstructed with metal brackets and pallets. b) Warehouse, east side door, discharges to outside exit route, obstructed by a trailer. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d). Gulfside Supply, Inc. dba Gulfeagle Supply was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.37(a)(3), which was contained in OSHA Inspection number 1635443, Citation 1, Item number 1b and was affirmed as a final order on April 18, 2023, with respect to a workplace located at 1820 N. Central Avenue, Chicago, Illinois 60639.
Recent events (2)
- — I (R) $0
- — Z (R) $0
1910.38 F01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.38(f)(1): The employer did not review the emergency action plan with each employee covered by the plan when the employee was assigned initially to a job: On or about May 11th, 2023, employees perform inventory, shipping, and receiving duties at 375 Renner Dr., Elgin, IL, without the benefit of a communicated emergency action plan. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1):Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: On or about May 11th, 2023, the primary warehouse electrical panel was blocked with a large extension ladder, impeding safe operation and maintenance. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at GULFSIDE SUPPLY, INC. DBA GULFEAGLE SUPPLY
SAINT PETERSBURG, FL—2026-02-26
GULFSIDE SUPPLY, INC. DBA GULFEAGLE SUPPLY
CHICAGO, IL—2023-06-28 00:00:00
GULFSIDE SUPPLY, INC. DBA GULFEAGLE SUPPLY
CHICAGO, IL—2022-11-21 00:00:00
GULFSIDE SUPPLY, INC. DBA GULFEAGLE SUPPLY
View GULFSIDE SUPPLY, INC. DBA GULFEAGLE SUPPLY's full OSHA safety record →
More inspections in this industry (NAICS 423330)
KLAMATH FALLS, OR—2026-07-07
317744722 - NORTHWEST QUALITY ROOFING LLC
PORT ORCHARD, WA—2026-06-25
WA317991918 - CONVOY SUPPLY INC
ROSEVILLE, CA—2026-06-23
RWC BUILDING PRODUCTS - SACRAMENTO
PASADENA, TX—2026-06-22
IDEAL PRODUCTS OF AMERICA
HILLSBORO BEACH, FL—2026-06-12
LA ROOFING GROUP INC
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346695067.