MOUNTAIN TOP, PA —
OSHA Inspection: CRESTWOOD MEMBRANES, INC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of CRESTWOOD MEMBRANES, INC in 755 OAK HILL ROAD, MOUNTAIN TOP, PA 18707 (NAICS 326113). OSHA activity number 346780687.
Where did this inspection happen?
- Establishment
- CRESTWOOD MEMBRANES, INC
- Site address
- 755 OAK HILL ROAD
- City
- MOUNTAIN TOP
- State
- PA
- ZIP
- 18707
- Mailing
- 755 OAK HILL ROAD, MOUNTAIN TOP, PA 18707
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326113
- Employees
- 165
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.101 A
- Issued
- Abate by
- Penalty
- Initial $8036.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.101(a): The employer did not determine that compressed gas cylinders under his control were in a safe condition to the extent that can be determined by visual or other inspections conducted as prescribed in the Hazardous Materials Regulations: a) Maintenance Area: Employees were exposed to fire hazards due to acetylene and oxygen cylinders being stored within an unsecured cylinder rack, on or about June 19, 2023. Abatement certification required.
Recent events (3)
- — F (S) $0
- — C (S) $8036
- — Z (S) $8036
1910.106 D04 I
- Issued
- Abate by
- Penalty
- Initial $10046.00 · Current $6500.00 Reduced
General-duty citation text
29 CFR 1910.106(d)(4)(i): Opening(s) from inside flammable and combustible storage room(s) into other rooms or buildings were not provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height: (a) Flammable Storage: Employees were exposed to fire hazards due to flammable liquids, such as printing ink, being stored within an interior room, that accessed other interior rooms, had sills or ramps less than 2.75 inches high, on or about June 19, 2023. Abatement certification required.
Recent events (3)
- — F (S) $6500
- — C (S) $10046
- — Z (S) $10046
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $15625.00 · Current $13500.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Calender 9 Line: Employer did not utilize specific procedures for the control of potentially hazardous energy when employees were engaged in cleaning and setup of Calendar 9 which has electrical, hydraulic, and pneumatic energy sources, on or about June 19, 2023. b) Calender 10 Line: Employer did not utilize specific procedures for the control of potentially hazardous energy when employees were engaged in cleaning and setup of Calendar 10 which has electrical, hydraulic, and pneumatic energy sources, on or about June 19, 2023. c) Calender 11 Line: Employer did not utilize specific procedures for the control of potentially hazardous energy when employees were engaged in cleaning and setup of Calendar 11 which has electrical, hydraulic, and pneumatic energy sources, on or about June 19, 2023. Abatement certification and documentation required.
Recent events (3)
- — F (S) $13500
- — C (S) $15625
- — Z (S) $15625
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: a) 755 Oak Hill Road, Mountain Top, PA 18707: the employer's energy control procedure, document 10.4.6 Lockout tagout program for i2M did not provide the specific procedural steps for isolating, blocking, securing machine, placement of lockout devices and the requirements to verify the effectiveness of the lockout tagout devices for the calenders, on or about June 19, 2023 Abatement certification and documentation required.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Abate by
- Penalty
- Initial $15625.00 · Current $13500.00 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) Wintech Takeoff on Calender 10 line: Employees were exposed to crush-by hazards when performing cleaning and set-up operations due to a lack of any lockout/tagout devices being affixed while engaged in those activities, on or about June 19, 2023. b) Shredder Line: Employees were exposed to struck-by hazards when performing repairs of the main shredder drive motor due to the lack of any lockout/tagout devices being affixed, on or about June 19, 2023. Abatement certification and documentation required.
Recent events (3)
- — F (S) $13500
- — C (S) $15625
- — Z (S) $15625
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $15625.00 · Current $13500.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Rewinder 3: Employees unjamming Rewinder 3, Serial # 70240, were exposed to struck-by hazards from rotating parts and struck -by hazards due to inadequate guarding, on or about June 19, 2023. b) Wintech Take-Off on Calender 10 Line: Employees were exposed to crush-by hazards when operating the machinery due to a lack of guarding around the take-off roller. Abatement certification and documentation required.
Recent events (4)
- — P (S) $13500
- — F (S) $13500
- — C (S) $15625
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $6026.00 · Current $4000.00 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Slitter Machine: Employees using compressed air for cleaning of debris on the slitter, were exposed to flying particles due to the supplied compressed air exceeding 95psi, on or about June 19, 2023. Abatement certification required.
Recent events (3)
- — F (S) $4000
- — C (S) $6026
- — Z (S) $6026
1910.243 B02
- Issued
- Abate by
- Penalty
- Initial $6026.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.243(b)(2): Airhose and hose connections used for conducting compressed air to utilization equipment was not designed for the pressure and service to which they were subjected: a) Slitter: Employees were exposed to struck-by hazards due to the use of worm gear hose clamps on airlines containing 95psi compressed air, on or about June 19, 2023. b) Sheeter: Employees were exposed to struck-by hazards due to the use of worm gear hose clamps on airlines containing 110psi compressed air, on or about June 19, 2023. Abatement certification required.
Recent events (3)
- — F (S) $0
- — C (S) $6026
- — Z (S) $6026
1910.253 B04 I
- Issued
- Abate by
- Penalty
- Initial $8036.00 · Current $5000.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire; or in an acetylene generator compartment: a) Maintenance Area: Employees were exposed to fire hazards due to cylinders containing acetylene and oxygen being stored together, on or about June 19, 2023. Abatement certification required.
Recent events (3)
- — F (S) $5000
- — C (S) $8036
- — Z (S) $8036
1910.303 H03
- Issued
- Abate by
- Penalty
- Initial $6026.00 · Current $4000.00 Reduced
General-duty citation text
29 CFR 1910.303(h)(3): Energized parts of electric equipment rated over 600 volts, nominal, were exposed and the minimum clear work space was less than 3 feet wide (measured parallel to the equipment): (a) Maintenance Uniform Storage: Employees were exposed to shock hazards due to not maintaining three (3) feet or more of workspace in front of 2400-volt switch gear, on or about June 19, 2023. Abatement certification required.
Recent events (3)
- — F (S) $4000
- — C (S) $6026
- — Z (S) $6026
More inspections at CRESTWOOD MEMBRANES, INC
MOUNTAIN TOP, PA—2025-04-08 00:00:00
CRESTWOOD MEMBRANES, INC.
MOUNTAIN TOP, PA—2021-10-13 00:00:00
CRESTWOOD MEMBRANES, INC.
MOUNTAIN TOP, PA—2017-12-11 00:00:00
CRESTWOOD MEMBRANES, INC.
MOUNTAIN TOP, PA—2016-11-17 00:00:00
CRESTWOOD MEMBRANES, INC.
View CRESTWOOD MEMBRANES, INC's full OSHA safety record →
More inspections in this industry (NAICS 326113)
NARRAGANSETT, RI—2026-07-09 00:00:00
ROGERS CORPORATION
RURAL RETREAT, VA—2026-07-07 00:00:00
KLOCKNER PENTAPLAST OF AMERICA, INC.
SUTTON, MA—2026-07-01 00:00:00
POLYVINYL FILMS, INC.
GARFIELD, NJ—2026-05-22 00:00:00
PRIMEX PLASTICS CORPORATION
FERNLEY, NV—2026-05-21 00:00:00
AGRU AMERICA, INC.
More inspections in PA
COLUMBIA, PA—2026-07-17 00:00:00
FOX TAPPING INC.
COLUMBIA, PA—2026-07-17 00:00:00
COLUMBIA WATER CO
WILKES BARRE, PA—2026-07-17 00:00:00
NEW ENTERPRISE STONE & LIME CO., INC.
PHILADELPHIA, PA—2026-07-16 00:00:00
MUKHLEEN GERNAROS PIZZA LLC DBA GENARO'S PIZZERIA AND STEAKS
PHILADELPHIA, PA—2026-07-16 00:00:00
CENTER CITY CONSTRUCTION AND DEVELOPMENT, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346780687.