MIDDLETOWN, NJ —
OSHA Inspection: WAVE ELECTRIC COMPANY LLC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of WAVE ELECTRIC COMPANY LLC in 1040 HWY 35, MIDDLETOWN, NJ 07748 (NAICS 238210). OSHA activity number 346822703.
Where did this inspection happen?
- Establishment
- WAVE ELECTRIC COMPANY LLC
- Site address
- 1040 HWY 35
- City
- MIDDLETOWN
- State
- NJ
- ZIP
- 07748
- Mailing
- 3 SHEILA DRIVE, TINTON FALLS, NJ 07724
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 12
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.416 A01
- Issued
- Abate by
- Penalty
- Initial $6250.00 · Current $6250.00
General-duty citation text
29 CFR 1926.416(a)(1): The employer permitted employees to work in close proximity to energized, unguarded, and ungrounded electric power circuits that the employee could contact in the course of their work: a) 1040 Hwy 35, Middletown, NJ: An employee was utilizing a Genie Lift, model Z-60, serial #Z6013-12480 in order to install electrical receptacles on the front of the building. The lift's boom made contact with a 72 KV powerline. The lift became energized, and the employee sustained an electrical shock. The employee was at a height of approximately twenty-one feet when he fell and sustained fatal injuries. Violation occurred on or about 07/11/23 NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $6250
- — C (S) $6250
- — Z (S) $6250
1926.453 B02 V
- Issued
- Abate by
- Penalty
- Initial $6250.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: Note: As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated a) 1040 Hwy 35, Middletown, NJ: An employee was utilizing a Genie Lift, model Z-60, serial #Z6013-12480 in order to install electrical receptacles on the front of the building. The employee was not attached to the basket by a lanyard. The employee was at a height of approximately twenty-one feet from the bottom of the platform to the ground. Employee sustained an electrical shock and fell from the basket, receiving fatal injuries. Violations occurred on or about 07/11/23 NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $6250
- — Z (S) $6250
1926.454 A01
- Issued
- Abate by
- Penalty
- Initial $6250.00 · Current $6250.00
General-duty citation text
29 CFR 1926.454(a)(1): The employer failed to have each employee who performs work while on a scaffold trained regarding the nature of any electrical hazards, fall hazards and falling object hazards in the work area. a) 1040 Hwy 35, Middletown, NJ: The employer did not provide training covering electrical hazards from equipment approaching or contacting energized power lines. The employee encroached on power lines making contact. Violation occurred on or about 07/11/23 b) 1040 Hwy 35, Middletown, NJ: The employer did not provide training covering fall hazards from operating an articulating boom lift. The Employee did not wear fall protection while at a height of approximately twenty one feet. Violation occurred on or about 07/11/23 NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $6250
- — C (S) $6250
- — Z (S) $6250
1904.40 A
- Issued
- Abate by
- Penalty
- Initial $893.00 · Current $893.00
General-duty citation text
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within four business hours. a) 1040 Hwy 35, Middletown, NJ: The employer failed to supply OSHA logs from 2020 to present. Logs were not maintained by the company. Violation occurred on or about 08/22/23 NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (O) $893
- — C (O) $893
- — Z (O) $893
More inspections in this industry (NAICS 238210)
PARKVILLE, MD—2026-07-15 00:00:00
THE POWER SOURCE, INC.
SOUTH BARRINGTON, IL—2026-07-15 00:00:00
EDGE ELECTRICAL SYSTEMS, LLC
LAYTON, UT—2026-07-14 00:00:00
LYNN WOODWARD ELECTRIC LLC
BRIDGEPORT, WV—2026-07-14 00:00:00
INFINITY ELECTRIC & SERVICE COMPANY, LLC
ANNAPOLIS, MD—2026-07-14 00:00:00
J.M. MULLEN ELECTRICAL SERVICES, INC.
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16 00:00:00
ENGLERT INC.
RIDGEFIELD, NJ—2026-07-16 00:00:00
COLORITE PLASTICS COMPANY
BERLIN, NJ—2026-07-16 00:00:00
URUS CONSTRUCTION CORPORATION
GLASSBORO, NJ—2026-07-15 00:00:00
GLASSBORO WATER & SEWER DEPARTMENT
FLANDERS, NJ—2026-07-15 00:00:00
TRI-STATE QUIKRETE
Source