OSHA Inspection: COOLSYS COMMERCIAL & INDUSTRIAL SOLUTIONS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of COOLSYS COMMERCIAL & INDUSTRIAL SOLUTIONS, INC. in 20951 OLD CUTLER ROAD, MIAMI, FL 33189 (NAICS 238220). OSHA activity number 347037491.

Watch Coolsys Commercial & Industrial Solutions, INC. — free Get an email when a new federal OSHA severe-injury report for Coolsys Commercial & Industrial Solutions, INC. is published. One employer, no account, unsubscribe in one click.
Site address
20951 OLD CUTLER ROAD
City
MIAMI
State
FL
ZIP
33189
Mailing
145 S. STATE COLLEGE BLVD, BREA, CA 92821
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238220
Employees
26
Ownership type
A

5 citations on file for this inspection.

1903.19 C01

Deleted Other-than-serious 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $1100.00 · Current $0.00 Reduced
29 CFR  1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  a. On or about July 3, 2024,  the employer failed to submit certification of corrective action for citation 1, item 1b, issued on April 8, 2024  with an abatement due date of  May 2, 2024.  b. On or about July 3, 2024,  the employer failed to submit certification of corrective action for citation 1, item 2, issued on April 8, 2024  with an abatement due date of May 2, 2024.
Recent events (3)
  • — J (O) $0
  • — C (O) $1100
  • — Z (O) $1100

1903.19 D01

Deleted Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required:   a. On or about July 3, 2024,  the employer failed to submit documentation and certification of corrective action for citation 1, item 1a, issued on April 8, 2024  with an abatement due date of  May 2, 2024.
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.28 B15

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $7835.00 · Current $7835.00
29 CFR 1910.28(b)(15): Walking-working surfaces not otherwise addressed. Except as provided elsewhere in this section or by other subparts of this part, the employer did not ensure each employee on a walking working surface 4 feet (1.2 m) or more above a lower level is protected from falling by one of the systems listed in 1910.28(b)(15)(i)-(iii):  On or about October 10, 2023 and at times prior, at 20951 Old Cutler Road, Cutler Bay, Florida 33189, an employee was exposed to a 10-foot fall hazard while replacing a condenser motor of a Seasons 4 custom-manufactured HVAC unit (i.e. Model VA065, Serial BD392102101) without being protected from falling.
Recent events (1)
  • — Z (S) $7835

1910.29 A02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.29(a)(2): The employer did not provide and install all fall protection systems and falling object protection this subpart requires, and comply with the other requirements in this subpart before any employee begins work that necessitates fall or falling object protection:  On or about October 10, 2023 and at times prior, at 20951 Old Cutler Road, Cutler Bay, Florida 33189, an employee was exposed to a 10-foot fall hazard while replacing a condenser motor of a Seasons 4 custom-manufactured HVAC unit (i.e. Model VA065, Serial BD392102101) without being protected from falling.
Recent events (1)
  • — Z (S) $0

1910.30 D

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $7835.00 · Current $7835.00
29 CFR 1910.30(d): Training that is understandable. The employer did not provide information and training to each employee in a manner that the employee understands:  On or about October 10, 2023 and at times prior, at 20951 Old Cutler Road, Cutler Bay, Florida 33189, the employer provided fall protection training in English to an employee who only speaks Spanish.
Recent events (1)
  • — Z (S) $7835

View COOLSYS COMMERCIAL & INDUSTRIAL SOLUTIONS, INC.'s full OSHA safety record →