Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CRASH CHAMPIONS LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CRASH CHAMPIONS LLC in 2620 6TH AVENUE, GARDEN CITY, CO 80631 (NAICS 811121). OSHA activity number 347094252.

Watch Crash Champions LLC — free Get an email when a new federal OSHA severe-injury report for Crash Champions LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CRASH CHAMPIONS LLC
Site address
2620 6TH AVENUE
City
GARDEN CITY
State
CO
ZIP
80631
Mailing
601 OAKMONT LANE #400, WESTMONT, IL 60559
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811121
Employees
20
Ownership type
A

8 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $5876.00 · Current $3526.00 Reduced
29 CFR  1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition.  (a)  2620 6th Avenue, Garden City, CO 80631 - Paint shop: On or about September 26, 2023, and at times prior, employees were exposed to trip hazards associated with divots in the floor.
Recent events (2)
  • — I (S) $3525.6
  • — Z (S) $5876

1910.178 G02

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $7835.00 · Current $4701.00 Reduced
29 CFR  1910.178(g)(2):  Facilities were not provided for flushing and neutralizing spilled electrolyte, for fire protection, for protecting charging apparatus from damage by trucks, and/or for adequate ventilation for dispersal of fumes from gassing batteries.  (a) 2620 6th Avenue Garden City, CO 80631 Detail shop:  On or about November 08, 2023, and at times prior, employees were exposed to fire hazards and chemical burns from charging a Toyota Electric Model 5FBE15 forklift using a Ferro 1500 series battery charger in that the forklift charging area did not provide materials for flushing and neutralizing spilled electrolyte, nearby fire extinguishers or damage protection for the charging apparatus.
Recent events (2)
  • — I (S) $4701
  • — Z (S) $7835

1910.178 P01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s0:  a) Crash Champions Collision Repair at 2620 6th Avenue Garden City, CO 80631 Detail shop:  On or about November 08, 2023, and at times prior, the employer did not ensure powered industrial trucks had been withdrawn from service while in an unsafe working condition in that corrosive buildup was located on the plastic casing of the battery and floor.  This condition exposed employees to serious eye and skin injuries.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B01

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $5876.00 · Current $3526.00 Reduced
29 CFR  1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees, in that the employer did not ensure the safety of the equipment pursuant to the considerations in sections (i) through (viii) of 29 CR 1910.303(b)(1):  (a) 2620 6th Avenue, Garden City, CO 80631 - body shop: On or about November 8, 2023, and at times prior, employees were exposed to electrical hazards while using a 220 Volt "The Maxi DF-505 Dent Pulling station," to repair automotive body damage, due to the damaged electrical cord on the machine from the A/C receptacle, and from the damage to electrical extension cord on both ends which relayed power to the device.
Recent events (2)
  • — I (S) $3525.6
  • — Z (S) $5876

1910.305 G01 IV A

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $5876.00 · Current $3526.00 Reduced
29 CFR  1910.305(g)(1)(iv)(A):  Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) Northwest Wall, 2620 6th Avenue, Garden City, CO 80631: On or around November 8, 2023, and at times prior, employees were exposed to fire and electrical hazards in that flexible cords in the paint shop were used in place of permanent wiring to power a motorized door lift.
Recent events (2)
  • — I (S) $3525.6
  • — Z (S) $5876

1910.37 B02

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  (a) 2620 6th Avenue, Garden City, CO 80631 - Autobody shop: On or around November 8, 2023 and at time prior, employees were exposed to entrapment hazards from exit doors not being clearly marked and visible with a sign reading "exit".
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.106 E09 III

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily:  (a) 2620 6th Avenue, Garden City, CO 80631 - Paint Shop: On or around June 14, 2023 and at time prior, employees were exposed to fire hazards while working in and around oily rag waste cans that were not emptied daily.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.243 B02

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.243(b)(2):  Airhose and hose connections used for conducting compressed air to utilization equipment was not designed for the pressure and service to which they were subjected.  (a) 2620 6th Avenue, Garden City, CO 80631 - Autobody shop: On or around November 8, 2023 and at time prior, employees in the paint shop were exposed to struck by hazards from an uncontrolled air hose in that the fitting, a worm-gear style hose clamp was not designed for the pressure of the pneumatic system.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View CRASH CHAMPIONS LLC's full OSHA safety record →