Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ALTIVIA SPECIALTY CHEMICALS, LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of ALTIVIA SPECIALTY CHEMICALS, LLC in 1901 WEST H STREET, LA PORTE, TX 77571 (NAICS 325110). OSHA activity number 347142911.

Watch Altivia Specialty Chemicals, LLC — free Get an email when a new federal OSHA severe-injury report for Altivia Specialty Chemicals, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1901 WEST H STREET
City
LA PORTE
State
TX
ZIP
77571
Mailing
1901 WEST H STREET, LA PORTE, TX 77571
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325110
Employees
78
Ownership type
A

3 citations on file for this inspection.

1910.119 D03 II

Other-than-serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $16131.00 · Current $16131.00
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices.  On or about 12/04/2023, in the cold vents unit at ALTIVIA in La Porte, Texas, the program that documents the suitability for service in accordance with Part 2 of API 579/ASME FFS-1 for fiber reinforced polymer piping, including, but not limited to circuit 8320-29-134, can be improved
Recent events (2)
  • — I (O) $16131
  • — Z (S) $16131

1910.119 J02

Other-than-serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $16131.00 · Current $0.00 Reduced
29 CFR  1910.119(j)(2):The employer did not establish or implement written procedures to maintain the on-going integrity of process equipment:  On or about 12/04/2023, in the cold vents unit at ALTIVIA in La Porte, Texas, the written procedures for nondestructive testing (NDE) of fiber reinforced polymer piping can be improved.
Recent events (2)
  • — I (O) $0
  • — Z (S) $16131

1910.119 J04 II

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $16131.00 · Current $0.00 Reduced
29 CFR  1910.119(j)(4)(ii): The inspection and testing procedures did not follow recognized and generally accepted good engineering practices.  On or about 12/05/2023, at Cold Vents Unit, the employer failed to test fiberglass reinforced piping that includes but is not limited to circuit 8320-29-134
Recent events (2)
  • — I (S) $0
  • — Z (S) $16131