SHELL LAKE, WI —
OSHA Inspection: NORTHSIDE EXTERIORS L.L.C.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NORTHSIDE EXTERIORS L.L.C. in 505 PINE RIDGE DRIVE, SHELL LAKE, WI 54871 (NAICS 238160). OSHA activity number 347144685.
Where did this inspection happen?
- Establishment
- NORTHSIDE EXTERIORS L.L.C.
- Site address
- 505 PINE RIDGE DRIVE
- City
- SHELL LAKE
- State
- WI
- ZIP
- 54871
- Mailing
- 6325 HAMPSHIRE AVE. N, BROOKLYN PARK, MN 55428
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B10
- Issued
- Abate by
- Penalty
- Initial $4688.00 · Current $3282.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: (a) Commercial rooftop, various locations; Workers engaged in steel roof panel replacement activities from a low-slope (4:12) roof were not protected from falls while working at approximate heights ranging between 10-feet, 4-inches to 25-feet or more above ground level.
Recent events (2)
- — I (S) $3281.6
- — Z (S) $4688
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $4688.00 · Current $3282.00 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) Commercial rooftop, various locations; Workers exposed to fall hazards while working from a low-slope (4:12) roof to replace steel roofing panels at approximate heights ranging between 10-feet, 4-inches to 25-feet or more above ground level, were not trained on fall hazard recognition and/or mitigation methods.
Recent events (2)
- — I (S) $3281.6
- — Z (S) $4688
More inspections in this industry (NAICS 238160)
PORTLAND, OR—2026-07-17 00:00:00
317744797 - JBC ROOFING LLC
MERIDIAN, ID—2026-07-17 00:00:00
COBRA'S ROOFING LLC
SYRACUSE, NY—2026-07-17 00:00:00
NAMICELA HOME SOLUTIONS INC
BRADLEY, IL—2026-07-16 00:00:00
JUAN CRUZ DBA ROOFBOYS LLC
PONCE INLET, FL—2026-07-16 00:00:00
RESOLUTE ROOFING LLC
More inspections in WI
GREEN BAY, WI—2026-07-17 00:00:00
PTS CONTRACTORS, INC.
WAUSAU, WI—2026-07-16 00:00:00
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15 00:00:00
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15 00:00:00
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15 00:00:00
TERONOMY BUILDERS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347144685.