OSHA Inspection: PUGET SOUND NAVAL SHIPYARD, CODE 950 (ELECTRICAL)

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PUGET SOUND NAVAL SHIPYARD, CODE 950 (ELECTRICAL) in USS NIMITZ 1400 FARRAGUT AVENUE, BREMERTON, WA 98314 (NAICS 928110). OSHA activity number 347283525.

Watch Puget Sound Naval Shipyard, Code 950 (Electrical) — free Get an email when a new federal OSHA severe-injury report for Puget Sound Naval Shipyard, Code 950 (Electrical) is published. One employer, no account, unsubscribe in one click.
Site address
USS NIMITZ 1400 FARRAGUT AVENUE
City
BREMERTON
State
WA
ZIP
98314
Mailing
1400 FARRAGUT AVENUE, BREMERTON, WA 98314
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
13534
Ownership type
D

1 citation on file for this inspection.

1915.181 B

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1915.181(b): Before employees were permitted to work on an electrical circuit the circuit was not deenergized:  a) USS Nimitz, on or about February 6, 2024, Shop 51 employees were required to work on energized wiring while performing inspection, repair, and cleaning of components within a breaker panel. The task required employees to disconnect two energized wires determined to have a voltage of approximately 28VDC from a terminal board, then isolate the wires with shrink sleeving, and hang the wires within the electrical panel. The wires remained energized for the duration of the repair.  Note for reference: 29 CFR 1915.181(b) in full: Before an employee is permitted to work on an electrical circuit, except when the circuit must remain energized for testing and adjusting, the circuit shall be deenergized and checked at the point at which the work is to be done to insure (sic) that it is actually deenergized. When testing or adjusting an energized circuit a rubber mat, duck board, or other suitable insulation shall be used underfoot where an insulated deck does not exist.