SAVANNAH, GA —
OSHA Inspection: PRECISION PROTECTIVE COATINGS
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of PRECISION PROTECTIVE COATINGS in 8 TELFAIR ROAD, SAVANNAH, GA 31415 (NAICS 333613). OSHA activity number 347356818.
Where did this inspection happen?
- Establishment
- PRECISION PROTECTIVE COATINGS
- Site address
- 8 TELFAIR ROAD
- City
- SAVANNAH
- State
- GA
- ZIP
- 31415
- Mailing
- 8 TELFAIR ROAD, SAVANNAH, GA 31415
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333613
- Employees
- 46
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.1026 C
- Issued
- Abate by
- Penalty
- Initial $8067.00 · Current $4034.00 Reduced
General-duty citation text
29 CFR 1910.1026(c): Employees were exposed to an airborne concentration of chromium (VI) which exceeded 5 micrograms per cubic meter of air, as an 8-hour time-weighted average: a.) At 8 Telfair Road Savannah, GA 31415 in the paint spray area: On or about April 2, 2024, the employer exposed employees to hexavalent chromium hazards, in that an employee was priming aerospace parts and was exposed to hexavalent chromium at an 8-hour TWA of 0.00662894 mg/m3. This level exceeded the permissible exposure level (PEL) of 0.005 mg/m3 by 1.3 times. The exposure was derived from two samples collected for a cumulative 302 minute period. Exposure calculations included a zero increment for the time not sampled.
Recent events (2)
- — I (S) $4033.5
- — Z (S) $8067
1910.1026 F01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1026(f)(1)(i): Feasible engineering controls and work practices were not instituted to reduce and maintain employee exposures to chromium (VI) at or below the permissible exposure limit: a.) At 8 Telfair Road Savannah, GA 31415 in the paint spray booth 1,2 and the sanding booth: On or about April 2, 2024, the employer exposed employees to hexavalent chromium hazards, in that an employee was priming aerospace parts and was exposed to hexavalent chromium at an 8-hour TWA of 0.00662894 mg/m3. This level exceeded the permissible exposure level (PEL) of 0.005 mg/m3 by 1.3 times. The exposure was derived from two samples collected for a cumulative 302 minute period. Exposure calculations included a zero increment for the time not sampled.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1026 H01
- Issued
- Abate by
- Penalty
- Initial $11292.00 · Current $5646.00 Reduced
0689
General-duty citation text
29 CFR 1910.1026(h)(1): A hazard was present or was likely to be present from skin or eye contact with chromium (VI); however, the employer did not provide appropriate personal protective clothing and equipment at no cost to employees, and/or did not ensure that employees used such clothing and equipment: a.) At 8 Telfair Road, Savannah, GA 31415: On or about March 19, 2024, and at times prior to, the employer exposed employees to hexavalent chromium hazards in that the employer did not ensure employees performing painting operations utilized PPE properly when working with hexavalent chromium compounds.
Recent events (2)
- — I (S) $5646
- — Z (S) $11292
1910.1026 J01 I
- Issued
- Abate by
- Penalty
- Initial $8067.00 · Current $4034.00 Reduced
0689
General-duty citation text
29 CFR 1910.1026(j)(1)(i): The employer did not ensure that all surfaces were maintained as free as practicable of accumulations of chromium (VI). a.) At 8 Telfair Road, Savannah, GA 31415 in the breakroom: On or about April 2, 2024, and at times prior to, the employer exposed employees to hexavalent chromium hazards in that the employer did not keep surfaces free from accumulation of hexavalent chromium in that hexavalent chromium was detected at levels of 0.357 ug on the breakroom doorknob where employees were not mandated to wear PPE and utilized frequently for breaks. b.) At 8 Telfair Road, Savannah, GA 31415 in the process line preparation area: On or about April 2, 2024, and at times prior to, the employer did not keep surfaces free from accumulation of hexavalent chromium in that hexavalent chromium was detected at levels of 0.422 ug and 0.325 ug on the handrail and table, respectively, exposing employees to hexavalent chromium hazards.
Recent events (2)
- — I (S) $4033.5
- — Z (S) $8067
1910.178 L04 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a.) At 8 Telfair Road Savannah, GA 31415: On or about March 19, 2024, the employer exposed employees to struck-by hazards, in that forklift operator evaluations were not conducted at least once every three years for employees who operated forklifts on a daily basis.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at PRECISION PROTECTIVE COATINGS
SAVANNAH, GA—2025-04-02
PRECISION PROTECTIVE COATINGS
View PRECISION PROTECTIVE COATINGS's full OSHA safety record →
More inspections in this industry (NAICS 333613)
SIOUX FALLS, SD—2026-07-10
DMG, INC.
WARREN, MI—2026-05-21
MURRAY SPROCKETS INC DBA ABC MURRAY SPROCKETS INC
SAGINAW, MI—2026-04-22
SAGINAW BEARING COMPANY
SULLIVAN, IL—2026-04-17
HYDRO-GEAR LIMITED PARTNERSHIP
RIALTO, CA—2026-04-17
NP MECHANICAL, INC
More inspections in GA
ROME, GA—2026-07-13
CAMP INDUSTRIES
SOUTH FULTON, GA—2026-07-10
REEDWICK, LLC
CONYERS, GA—2026-07-10
GOLDEN STATE FOODS
DALTON, GA—2026-07-10
ENGINEERED FLOORS, LLC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
Source