SCHAUMBURG, IL —
OSHA Inspection: XOLOS LOPEZ CONSTRUCTION LLC DBA LOPEZ ROOFING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of XOLOS LOPEZ CONSTRUCTION LLC DBA LOPEZ ROOFING in 350 W. SCHAUMBURG ROAD, SCHAUMBURG, IL 60194 (NAICS 238160). OSHA activity number 347510141.
Where did this inspection happen?
- Establishment
- XOLOS LOPEZ CONSTRUCTION LLC DBA LOPEZ ROOFING
- Site address
- 350 W. SCHAUMBURG ROAD
- City
- SCHAUMBURG
- State
- IL
- ZIP
- 60194
- Mailing
- 143 FALCON CREST TRAIL, JONESBORO, GA 30238
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 15
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.300 B02
- Issued
- Penalty
- Initial $6084.00 · Current $3333.00 Reduced
General-duty citation text
29 CFR 1926.300(b)(2): Moving part(s) of equipment exposed to contact by employees or which otherwise created a hazard, were not guarded: a) On or about May 28, 2024, the belt and pulley on a Rigid air compressor used to supply pneumatic power to nail guns for the performance of roofing work was not guarded to prevent contact with moving parts. a) On or about May 28, 2024, the belt and pulley on an Ingersoll Rand air compressor used to supply pneumatic power to nail guns for the performance of roofing work was not guarded to prevent contact with moving parts. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (S) $3333.34
- — Z (S) $6084
1926.501 B10
- Issued
- Penalty
- Initial $6084.00 · Current $3333.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a) On or about May 28, 2024, employees were exposed to the hazard of falling approximately 9 feet while engaged in roofing activities without the use of fall protection or safety monitoring. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (S) $3333.34
- — Z (S) $6084
1926.1053 B22
- Issued
- Penalty
- Initial $6084.00 · Current $3333.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(22): Employees using ladders were carrying objects or loads that could cause the employee to lose balance and fall: a) On or about May 28, 2024, employees were exposed to the hazard of falling from elevations up to approximately 9 feet when climbing a portable extension ladder while carrying materials to a roof deck landing surface. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (S) $3333.32
- — Z (S) $6084
1910.178 L06
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(6): Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation. 29 CFR 1926.602(d) NOTE: The requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.178(l) of this chapter. a) On or about May 28, 2024, the employer did not certify that each forklift operator had been trained and evaluated. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238160)
PORTLAND, OR—2026-07-17 00:00:00
317744797 - JBC ROOFING LLC
MERIDIAN, ID—2026-07-17 00:00:00
COBRA'S ROOFING LLC
SYRACUSE, NY—2026-07-17 00:00:00
NAMICELA HOME SOLUTIONS INC
BRADLEY, IL—2026-07-16 00:00:00
JUAN CRUZ DBA ROOFBOYS LLC
PONCE INLET, FL—2026-07-16 00:00:00
RESOLUTE ROOFING LLC
More inspections in IL
FRANKFORT, IL—2026-07-17 00:00:00
QUANTUM TECHNICAL SERVICES INC.
ROCK ISLAND, IL—2026-07-17 00:00:00
AUGUSTANA COLLEGE
WASHINGTON, IL—2026-07-17 00:00:00
SUNRUN INSTALLATION SERVICES, INC.
FOREST PARK, IL—2026-07-17 00:00:00
CONSERVATION OF SCULPTURE & OBJECTS STUDIO, INC.
BLUE ISLAND, IL—2026-07-17 00:00:00
PROFLOW PUMPING SOLUTIONS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347510141.