PEORIA, IL —
OSHA Inspection: ENERGY RESOURCE SPECIALIST, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ENERGY RESOURCE SPECIALIST, INC. in 1015 E MOSSVILLE ROAD, PEORIA, IL 61615 (NAICS 238160). OSHA activity number 347558215.
Where did this inspection happen?
- Establishment
- ENERGY RESOURCE SPECIALIST, INC.
- Site address
- 1015 E MOSSVILLE ROAD
- City
- PEORIA
- State
- IL
- ZIP
- 61615
- Mailing
- 20956 DEER BLUFFS ROAD, CHILLICOTHE, IL 61523
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.20 B02
- Issued
- Abate by
- Penalty
- Initial $2765.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials, and equipment to be made by a competent person(s): On or about June 17, 2024, employees were exposed to fall hazards and chemical irritants while performing roofing operations because the employer did not ensure a competent person conducted frequent and regular inspections of the worksite and equipment to identify the workplace hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $2765
1926.501 B10
- Issued
- Abate by
- Penalty
- Initial $3457.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, warning line system and personal fall arrest system, or warning line system and safety monitoring system; or, on roofs 50 feet (15.25 m) or less in width, the use of a safety monitoring system alone: On or about June 17, 2024, employees were exposed to a fall hazard of up to 10 feet while installing roofing material because suitable fall protection system was not used.
Recent events (2)
- — I (O) $2500
- — Z (S) $3457
1926.503 A02 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(a)(2)(iv): The employer did not ensure that each employee was trained, as necessary by a competent person in the role of each employee in the safety monitoring system where the system was used: On or about June 17, 2024, an employee performing roofing operations was exposed to fall hazards of up to 10 feet and the safety monitor was not monitoring each employee engaged in the work.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 F06 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: On or about June 17, 2024, employees were exposed to paint containing chemical irritants and the secondary container(s) was not labeled, tagged, or marked with the contents inside.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at ENERGY RESOURCE SPECIALIST, INC.
TUSCOLA, IL—2016-06-02 00:00:00
ENERGY RESOURCE SPECIALIST, INC.
View ENERGY RESOURCE SPECIALIST, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347558215.