Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ERICK HERNANDEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ERICK HERNANDEZ in 1230 WEDGEWORTH DR, FORNEY, TX 75126 (NAICS 238160). OSHA activity number 347581340.

Watch Erick Hernandez — free Get an email when a new federal OSHA severe-injury report for Erick Hernandez is published. One employer, no account, unsubscribe in one click.
Establishment
ERICK HERNANDEZ
Site address
1230 WEDGEWORTH DR
City
FORNEY
State
TX
ZIP
75126
Mailing
1016 NEWINGTON CIR, FORNEY, TX 75126
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
15
Ownership type
A

3 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3687.00 · Current $2212.00 Reduced
29 CFR  1926.100(a):Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  a.  On or about June 26, 2024, at the jobsite, employees conducting roofing installation work were not wearing hard hats and were exposed to overhead hazards from workers working above them.
Recent events (2)
  • — I (S) $2212.2
  • — Z (S) $3687

1926.501 B13

Serious Gravity 10 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $6452.00 · Current $3871.00 Reduced
29 CFR  1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a.   On or about June 26, 2024, at the jobsite, employees engaged in roofing installation work in a two-story residential house roof at heights greater than 6 feet did not have fall protection and were exposed to fall hazards.
Recent events (2)
  • — I (S) $3871.2
  • — Z (S) $6452

1926.1053 B01

Serious Gravity 10 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $6452.00 · Current $3871.00 Reduced
29 CFR  1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) On or about June 26, 2024, on the north side and south side of the house, employees were accessing a two-story roof with ladders that did not extend 3 feet above the roof line.
Recent events (2)
  • — I (S) $3871.2
  • — Z (S) $6452

View ERICK HERNANDEZ's full OSHA safety record →

RNWBL

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347581340.