Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: UNITED STATES DEPARTMENT OF AGRICULTURE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of UNITED STATES DEPARTMENT OF AGRICULTURE in 29847 SEWARD HWY, SEWARD, AK 99664 (NAICS 115310). OSHA activity number 347668410.

Watch United States Department OF Agriculture — free Get an email when a new federal OSHA severe-injury report for United States Department OF Agriculture is published. One employer, no account, unsubscribe in one click.
Site address
29847 SEWARD HWY
City
SEWARD
State
AK
ZIP
99664
Mailing
29847 SEWARD HWY, SEWARD, AK 99664
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
115310
Employees
60
Ownership type
D

7 citations on file for this inspection.

1910.22 D01

Serious Gravity 5 2 instances 60 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(d)(2):  The employer did not ensure that hazardous conditions on walking-working surfaces are corrected or repaired before an employee uses the walking-working surface.  a)  Warehouse Stairs:  On or about July 30, 2024, spalling, damaged concrete on the stairs, exposing employees to trip and fall hazards.  b)  Compound:  On or about July 30, 2024,  the compound parking lot was uneven, exposing employees to tripping and fall hazards.
Recent events (1)
  • — Z (S) $0

1910.37 A03

Serious Gravity 5 3 instances 60 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(a)(3):  Exit route(s) were not kept free and unobstructed:  a) Carpentry Shop:  On or about July 30, 2024, several 2/4's blocked an exit door/path impeding timely egress, exposing employees to fire hazards.  b) Warehouse Vehicle Bay:  On or about July 30, 2024, a ladder and various pieces of equipment blocked an exit door/path impeding timely egress, exposing employees to fire hazards.  c) Warehouse Work Bench:  On or about July 30, 2024, a ladder and various pieces of equipment blocked an exit door/path impeding timely egress, exposing employees to fire hazards.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.212(a)(1):  Machine guarding was not provided to protect operator(s) and other employees from hazard(s):  a)  Carpentry Shop:  On or about July 30, 2024, a Craftsman 15 1/2" Drill Press was not guarded at the point of operations, exposing employee to struck by and caught in hazards.  b) Warehouse:  On or about July 30, 2024, a Rockwell 15" Drill Press was not guarded at the point of operations, exposing employee to struck by and caught in hazards.
Recent events (1)
  • — Z (S) $0

1910.304 G06 IV B

Serious Gravity 5 1 instance 60 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.304(g)(6)(iv)(B):  The receptacle was located in a wet or damp environment and was not grounded:   a) Maintenance Shop:  On or about July 30, 2024, an electrical outlet was without a Ground Fault Circuit Interrupter  in near proximity of a bathroom sink, exposing employees to electrical hazards.
Recent events (1)
  • — Z (S) $0

1910.157 E02

Other-than-serious 1 instance 60 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(2):  Portable fire extinguishers were not visually inspected at least monthly:  a)  Compound:  On or about July 30, 2024,  portable fire extinguisher(s) monthly visual inspections were not being conducted, exposing employees to fire hazards.
Recent events (1)
  • — Z (O) $0

1910.303 B02

Other-than-serious 1 instance 60 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2):  Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a)  Main Office:  On or about July 30, 2024 a Relocatable Power Tap (RPT/Surge Protector) was connected to another RPT, exposing employees to fire and electrical shock hazards.
Recent events (1)
  • — Z (O) $0

1910.303 G01 I B

Other-than-serious 1 instance 60 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1)(i)(B):  For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the width of the working space in front of electrical equipment was less than the width of the equipment or 762 mm (30 inches), whichever was greater :  a) Carpentry Shop:  On or about July 30, 2024, an electrical panel was blocked by a tools cadie, exposing employee to electrical hazards.
Recent events (1)
  • — Z (O) $0

View UNITED STATES DEPARTMENT OF AGRICULTURE's full OSHA safety record →