Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SHAMROCK ROOFING

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of SHAMROCK ROOFING in 4008 WALDEN AVE, LANCASTER, NY 14086 (NAICS 238160). OSHA activity number 347758989.

Watch Shamrock Roofing — free Get an email when a new federal OSHA severe-injury report for Shamrock Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
SHAMROCK ROOFING
Site address
4008 WALDEN AVE
City
LANCASTER
State
NY
ZIP
14086
Mailing
25 NORTHINGTON DRIVE, EAST AMHERST, NY 14051
Inspection type
Programmed Related (J)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.501 B10

Serious Gravity 1 1 instance 4 exposed
Issued
Penalty
Initial $1998.00 · Current $1998.00
29 CFR  1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system  a) On or about 07/12/2024, at a  residential roofing project located at 4408 Walden Ave in Lancaster, NY.; employees were installing roofing material on a section of roof with an 4 in 12 pitch and an eave height of approximately 15 feet at the front and rear of the building. Employees were not utilizing fall protection.  NO ABATEMENT DOCUMENTATION REQUIRED
Recent events (1)
  • — Z (S) $1998

1926.1053 B01

Serious Gravity 1 1 instance 4 exposed
Issued
Penalty
Initial $1998.00 · Current $1998.00
29 CFR  1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed.  a) On or about 07/12/2024 at the roof area of the site, side rails of the extension ladder extended 1 feet above the upper landing surface being accessed.  NO ABATEMENT CERTIFICATION REQUIRED