CARROLLTON, OH —
OSHA Inspection: MC ORLANDO CONSTRUCTION LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MC ORLANDO CONSTRUCTION LLC in 198 3RD ST. SE, CARROLLTON, OH 44615 (NAICS 238160). OSHA activity number 347800922.
Where did this inspection happen?
- Establishment
- MC ORLANDO CONSTRUCTION LLC
- Site address
- 198 3RD ST. SE
- City
- CARROLLTON
- State
- OH
- ZIP
- 44615
- Mailing
- 920 BEDFORD AVE. SW, CANTON, OH 44710
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $2765.00 · Current $1383.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a. On or about October 7, 2024, employees were operating pneumatic nail guns without eye protection, thereby exposing employees to struck-by hazards.
Recent events (2)
- — I (S) $1382.5
- — Z (S) $2765
1926.501 B13
- Issued
- Penalty
- Initial $4839.00 · Current $2420.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. a. On or about October 7, 2024, the employer did not ensure that fall protection was utilized by employees engaging in roofing activities to a two-story residential house, thereby exposing the employees to fall hazards greater than 14 feet.
Recent events (2)
- — I (S) $2419.5
- — Z (S) $4839
1926.1053 B01
- Issued
- Penalty
- Initial $4839.00 · Current $2420.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. a. On or about October 7, 2024, the employer did not ensure that extension ladders used to gain access to the first-story eave, extended at least 3 feet above the upper landing surface, thereby exposing the employees to fall hazards greater than 14 feet.
Recent events (2)
- — I (S) $2419.5
- — Z (S) $4839
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16 00:00:00
MARVIN PINERA
CARSON CITY, NV—2026-07-16 00:00:00
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16 00:00:00
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16 00:00:00
CARLOS CHE
BALTIMORE, MD—2026-07-16 00:00:00
VAL CONSTRUCTION INC
More inspections in OH
WELLINGTON, OH—2026-07-16 00:00:00
WHIRLAWAY CORPORATION
WAUSEON, OH—2026-07-16 00:00:00
WATSON WELL DRILLING INC.
SEVEN HILLS, OH—2026-07-15 00:00:00
STONEY ACRES BUILDERS LLC
SEVEN HILLS, OH—2026-07-15 00:00:00
GRB ENTERPRISES LLC
CHILLICOTHE, OH—2026-07-15 00:00:00
KENWORTH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347800922.