2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: POWER CONSTRUCTION, INC.

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of POWER CONSTRUCTION, INC. in 920 MAIN STREET, PENNSBURG, PA 18073 (NAICS 238170). OSHA activity number 347859621.

Watch Power Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Power Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
920 MAIN STREET
City
PENNSBURG
State
PA
ZIP
18073
Mailing
209 LAWRENCEVILLE ROAD, LAWRENCE TOWNSHIP, NJ 08648
Inspection type
Programmed Related (J)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238170
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2837.00 · Current $2128.00 Reduced
29 CFR  1926.100(a):  Employees working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  a)  Residential construction at 920 Main Street, Pennsburg, PA:  On or about November 4, 2024 employees were exposed to head injuries by falling or thrown debris as they were working at ground level below other workers who were working on the roof.
Recent events (2)
  • — I (S) $2128
  • — Z (S) $2837

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $4965.00 · Current $3724.00 Reduced
29 CFR  1926.501(b)(13):  Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, personal fall arrest systems,  or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is feasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:  a)  Residential construction at 920 Main Street, Pennsburg, PA:  On or about November 4, 2024, employees were exposed to fall hazards of 12 feet to the ground while performing roof replacement work on a pitched roof of a residential structure.  No personal fall protection or barrier guarding was being utilized.
Recent events (2)
  • — I (S) $3724
  • — Z (S) $4965

1926.1053 B01

Serious Gravity 1 2 instances 4 exposed
Issued
Penalty
Initial $2128.00 · Current $1596.00 Reduced
29 CFR  1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a)  Residential construction at 920 Main Street Pennsburg, PA: On or about November 4, 2024, employees utilized portable ladders to access a two story roof.  The ladders were not positioned at least 3 feet above the upper landing surface.
Recent events (2)
  • — I (S) $1596
  • — Z (S) $2128

View POWER CONSTRUCTION, INC.'s full OSHA safety record →