PRINCETON, TX —
OSHA Inspection: MAXIMINO GONZALEZ RUFINO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MAXIMINO GONZALEZ RUFINO in 705 CLOVER WOOD DR., PRINCETON, TX 75407 (NAICS 238160). OSHA activity number 348060591.
Where did this inspection happen?
- Establishment
- MAXIMINO GONZALEZ RUFINO
- Site address
- 705 CLOVER WOOD DR.
- City
- PRINCETON
- State
- TX
- ZIP
- 75407
- Mailing
- 527 GULLEDGE LANE, DALLAS, TX 75217
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $2837.00 · Current $1700.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1):29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles. a. On or about February 25, 2025, employees doing roofing work on a single-family home and not wearing eye protection using pneumatic nail guns.
Recent events (1)
- — Z (S) $2837
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $3500.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On or about February 25, 2025, employees engaged in roofing work were exposed to falls of more than 20-feet without fall protection.
Recent events (1)
- — Z (S) $4965
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On or about February 25, 2025, employees were accessing the roof of a two-story house with ladders that were not extended 3ft above the roof surface.
Recent events (1)
- — Z (S) $4965
More inspections in this industry (NAICS 238160)
PORTLAND, OR—2026-07-17 00:00:00
317744797 - JBC ROOFING LLC
MERIDIAN, ID—2026-07-17 00:00:00
COBRA'S ROOFING LLC
SYRACUSE, NY—2026-07-17 00:00:00
NAMICELA HOME SOLUTIONS INC
BRADLEY, IL—2026-07-16 00:00:00
JUAN CRUZ DBA ROOFBOYS LLC
PONCE INLET, FL—2026-07-16 00:00:00
RESOLUTE ROOFING LLC
More inspections in TX
RICHMOND, TX—2026-07-17 00:00:00
CORNELIUS NURSERIES, INC.
HOUSTON, TX—2026-07-17 00:00:00
HOLLOWAY HOUSTON, INC.
BONHAM, TX—2026-07-17 00:00:00
VOLUNTARY PURCHASING GROUPS, INC.
SNYDER, TX—2026-07-16 00:00:00
RNWBL
WICHITA FALLS, TX—2026-07-16 00:00:00
UNITED RENTALS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348060591.