Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BLUE RAVEN SOLAR, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BLUE RAVEN SOLAR, LLC in 5953 COURSE DRIVE, WESTERVILLE, OH 43081 (NAICS 238210). OSHA activity number 348220195.

Watch Blue Raven Solar, LLC — free Get an email when a new federal OSHA severe-injury report for Blue Raven Solar, LLC is published. One employer, no account, unsubscribe in one click.
Site address
5953 COURSE DRIVE
City
WESTERVILLE
State
OH
ZIP
43081
Mailing
1403 N 630 E, OREM, UT 84097
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238210
Employees
20
Ownership type
A

2 citations on file for this inspection.

1926.503 A02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $14188.00 · Current $14188.00
29 CFR 1926.503(a)(2): The employer shall assure that each employee has been trained, as necessary, by a competent person qualified in the following areas:   29 CFR 1926.503(a)(2)(ii): The correct procedures for erecting, maintaining, disassembling, and inspecting the fall protection systems to be used.  a) Blue Raven Solar, LLC, at a jobsite located at 5953 Course Drive, Westerville, OH 43081: On or about, and at times prior to April 30, 2025, the employer did not ensure that employees were trained on the correct procedures for erecting a fall protection/prevention system while engaged in residential construction activities. Employees were installing solar panels without ensuring that a compliant fall protection/prevention system was installed in that the employees installed anchor points with the flat end facing up, anchor point lag bolts were installed without embedment in the truss or embedded three inches, and no pilot holes were pre-drilled for the anchor point lag bolts. Additionally, employees did not select and install the correct lanyard for use on a roof with a pitch greater than 4:12 to limit slack in the system and reduce the potential for shock load to the anchor and/or user. This condition exposed employees to fall hazards between 11 and 17 feet.
Recent events (2)
  • — C (S) $14188
  • — Z (S) $14188

1926.502 A02

Repeat Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $99300.00 · Current $99300.00
29 CFR  1926.502(a)(2): The employer did not provide and install all fall protection systems required by this subpart for employee(s) and did not comply with all other pertinent requirements of this subpart before employee(s) began the work that necessitates the fall protection.   a) Blue Raven Solar, LLC, at a jobsite located at 5953 Course Drive, Westerville, OH 43081: On or about, and at times prior to April 30, 2025, employees installing solar panels on the roof of an existing residential home were not provided with a fall protection/prevention system that was capable of protecting employees from fall hazards between 11 and 17 feet on a roof with a 12:12 pitch.  Blue Raven Solar, LLC  was previously cited for a violation of this Occupational Safety and Health standard 29 CFR 126.502 (a)(2),which was contained in OSHA inspection number 1725979, citation number 1, item number 1. This citation as amended pursuant to the settlement agreement as violation of  OSH ACT of 1970 Section (5)(a)(1) and was affirmed as final order on July 9, 2024, with respect to a workplace located at 2013 Liberty Ln., Gurnee, IL 60031.
Recent events (2)
  • — C (R) $99300
  • — Z (R) $99300

View BLUE RAVEN SOLAR, LLC's full OSHA safety record →