Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: KW PROPERTY MANAGEMENT & CONSULTING, LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of KW PROPERTY MANAGEMENT & CONSULTING, LLC in 5005 COLLINS AVENUE, MIAMI, FL 33140 (NAICS 531311). OSHA activity number 348285701.

Watch KW Property Management & Consulting, LLC — free Get an email when a new federal OSHA severe-injury report for KW Property Management & Consulting, LLC is published. One employer, no account, unsubscribe in one click.
Site address
5005 COLLINS AVENUE
City
MIAMI
State
FL
ZIP
33140
Mailing
8200 NW 33RD STREET SUITE 300, MIAMI, FL 33122
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
531311
Employees
17
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $16550.00 · Current $11585.00 Reduced
OSH ACT of 1970 Section (5)(a)(1):The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to explosion and fire hazards:  a) On or about June 3, 2025, at the jobsite located at 5005 Collins Avenue, Miami, FL 33140, employees were exposed to explosion and fire hazards while performing torch soldering on water lines and drain valves adjacent to wall openings, where combustible material such as dryer lint and flammable gases were present or could accumulate.
Recent events (2)
  • — I (S) $11585
  • — Z (S) $16550

1910.132 A

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $7566.00 · Current $4540.00 Reduced
29 CFR  1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:  a) On or about June 3, 2025, at the jobsite located at 5005 Collins Avenue, Miami, FL 33140, employees were exposed to burn hazards when soldering drain valves without the use of fire-retardant clothing.
Recent events (2)
  • — I (S) $4539.6
  • — Z (S) $7566

1910.132 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $7566.00 · Current $4540.00 Reduced
29 CFR  1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):  a) On or about June 3, 2025, at the jobsite located at 5005 Collins Avenue, Miami, FL 33140, the employer failed to develop a hazard assessment to determine and select the use of personal protective equipment while soldering.
Recent events (2)
  • — I (S) $4539.6
  • — Z (S) $7566

1910.133 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $7566.00 · Current $4540.00 Reduced
29 CFR  1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  a) On or about June 3, 2025, at the jobsite located at 5005 Collins Avenue, Miami, FL 33140, employees were exposed to eye burn hazards when soldering drain valves without the use of eye protection.
Recent events (2)
  • — I (S) $4539.6
  • — Z (S) $7566

1910.138 A

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $7566.00 · Current $4540.00 Reduced
29 CFR  1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes.  a) On or about June 3, 2025, at the jobsite located at 5005 Collins Avenue, Miami, FL 33140, employees were exposed to burn hazards when soldering drain valves without the use of appropriate hand protection.
Recent events (2)
  • — I (S) $4539.6
  • — Z (S) $7566

1910.1200 G08

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(g)(8):  The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical  a) On or about June 3, 2025, at the jobsite located at 5005 Collins Avenue, Miami, FL 33140, safety data sheets were not available for hazardous chemicals that employees worked with, such as but not limited to, solder wire and propane Benzomatic torches.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348285701.