Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MAYKEL CONSTRUCTION INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MAYKEL CONSTRUCTION INC in 11 AUBURN STREET, WOBURN, MA 01801 (NAICS 238170). OSHA activity number 348467283.

Watch Maykel Construction INC — free Get an email when a new federal OSHA severe-injury report for Maykel Construction INC is published. One employer, no account, unsubscribe in one click.
Site address
11 AUBURN STREET
City
WOBURN
State
MA
ZIP
01801
Mailing
141 PALMER STREET 1ST FLOOR, FALL RIVER, MA 02724
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238170
Employees
5
Ownership type
A

9 citations on file for this inspection.

1926.102 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $3972.00 · Current $1986.00 Reduced
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying objects while using a nail gun.  Location: Job site;  On or about 08/27/2025, employees were allowed to utilize pneumatic nail guns without proper eye/face protection to protect against flying objects or debris.
Recent events (2)
  • — I (S) $1986
  • — Z (S) $3972

1926.451 F07

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3972.00 · Current $1986.00 Reduced
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees selected by, and under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration.  Location: Job site;  On or about 08/27/2025, employees were allowed to utilize Alum-A-Pole pump jack scaffolding which was not erected by experienced employees under the supervision of a competent person qualified in scaffolding erection. The deficiencies with the pump jack scaffolding units which were not correctly erected or whose deficiencies were not identified and corrected prior to usage by a competent person are noted in the subsequent violations in 1-2-b through 1-2-f.
Recent events (2)
  • — I (S) $1986
  • — Z (S) $3972

1926.451 C02

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates and mud sills or other adequate firm foundation.  Location: Job site;  On or about 08/27/2025, the employer allowed employees to erect and work from a pump jack scaffolding that was 13.5-feet above the ground below and did not bear on base plates, mud sills, or other adequate firm foundation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 C03

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, posts, frames, and uprights were not plumb and braced to prevent swaying and displacement.  Location: Job site;   On or about 08/27/2025, employer allowed employees to utilize a pump jack scaffolding system where the post legs and frames were not plumb and braced to prevent swaying or displacement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 F06

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer than 10-feet to exposed and energized power lines.  Location: Job site;  On or about 08/27/2025, the employer erected and allowed employees to utilize an Alum-A-Pole pumpjack scaffolding system which was within 3-feet of energized power lines to the residence.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01 VII

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  Location: Job site;  On or about 08/27/2025, employees were allowed to work from a pump jack scaffold 13.5-feet above a lower level without the use or availability of a personal fall arrest system or guardrail system.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 J02

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.452(j)(2): Poles of pump jack scaffold were not secured to the structure by rigid triangular bracing, or equivalent, at the bottom point of the structure as necessary.  Location: Job site;  On or about 08/27/2025, employees were allowed to work from a pump jack scaffolding at a height of 13.5-feet and the poles/legs of the pumpjack scaffolding were not secured to the structure by rigid triangular bracing at both top and bottom.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $3972.00 · Current $1986.00 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b).  Location: Job site;  On or about 08/27/2025, an employee was allowed to perform siding work from the lower side roof of the residence from 8-feet above the ground below without any form of fall protection, such as guardrails, safety nets, or alternative protective measures.
Recent events (2)
  • — I (S) $1986
  • — Z (S) $3972

1926.1053 B04

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $3972.00 · Current $1986.00 Reduced
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed.  Location: Job site;  On or about 08/27/2025, employees were allowed to utilize a portable extension ladder for the following purpose(s) for which it was not designed or intended:  1) as the workbench and top rail of the work platform of the pump jack scaffolding.
Recent events (2)
  • — I (S) $1986
  • — Z (S) $3972

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348467283.