Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NORTHERN GROUP USA LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of NORTHERN GROUP USA LLC in 183 MAIN STREET, FOND DU LAC, WI 54935 (NAICS 236220). OSHA activity number 348473547.

Watch Northern Group USA LLC — free Get an email when a new federal OSHA severe-injury report for Northern Group USA LLC is published. One employer, no account, unsubscribe in one click.
Site address
183 MAIN STREET
City
FOND DU LAC
State
WI
ZIP
54935
Mailing
4829 SOUTH HATELY AVENUE, CUDAHY, WI 53110
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
5
Ownership type
A

5 citations on file for this inspection.

1910.134 E06 I

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $2412.00 · Current $1206.00 Reduced
29 CFR  1910.134(e)(6)(i): In determining the employee's ability to use a respirator, the employer shall obtain a written recommendation regarding the employee's ability to use the respirator from the physician or other licensed health care professional (PLHCP): [Construction Reference 29 CFR 1926.103]  On August 27, 2025, at a worksite located at 183 Main Street in Fond du Lac, Wisconsin; the employer did not obtain written recommendations from a PLHCP regarding employees' abilities to use tight-fitting negative pressure half-face respirators during the removal of asbestos containing floor tiles.
Recent events (2)
  • — I (S) $1206
  • — Z (S) $2412

1910.134 F01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 9020

29 CFR  1910.134(f)(1): The employer shall ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in this paragraph: [Construction Reference 29 CFR 1926.103]  On August 27, 2025, at a worksite located at 183 Main Street in Fond du Lac, Wisconsin; the employer did not ensure that an employee using tight-fitting facepiece respirators, during the removal of asbestos containing floor tiles, had passed an approved QLFT or QNFT.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 G01 I A

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 9020

29 CFR  1910.134(g)(1)(i)(A): The employer shall not permit respirators with tight-fitting facepieces to be worn by employees who have facial hair that comes between the sealing surface of the facepiece and the face or that interferes with valve function: [Construction Reference 29 CFR 1926.103]  On August 27, 2025, at a worksite located at 183 Main Street in Fond du Lac, Wisconsin; the employer permitted employees wearing tight-fitting negative pressure half-face respirators to have facial hair that came between the sealing surface of the facepieces of their respirators during the removal of asbestos containing floor tiles.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1051 A04

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $1929.00 · Current $964.00 Reduced
29 CFR  1926.1051(a)(4): When a building or structure has two or more points of access between levels, at least one point of access shall be kept clear to permit free passage of employees:  On August 27, 2025, at a worksite located at 183 Main Street in Fond du Lac, Wisconsin; the employer did not ensure that at least one point of access from the second story to the ground floor was kept clear to permit free passage of employees. The building's rear upstairs exit to the lower level was blocked by waste materials. The front passage was a stairwell which was not kept clear of stored materials, such as but not limited to PPE, tools, and clothing. Additionally, employees used the stairwell as a changing area; therefore, the passageway was not kept clear of other employees as they changed into and out of street clothes.
Recent events (2)
  • — I (S) $964
  • — Z (S) $1929

1926.416 E01

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.416(e)(1): Worn or frayed electric cords or cables shall not be used.  On August 27, 2025, at a worksite located at 183 Main Street in Fond du Lac, Wisconsin; the flexible exterior sheathing for the electrical extension cord, which was used to power air scrubbers (negative pressure air machines) was frayed which exposed the insulated conductor cables within.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348473547.