WESTFIELD, NJ —
OSHA Inspection: NOVA'S PAINTING AND REMODELING LLC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of NOVA'S PAINTING AND REMODELING LLC in 310 SOUTH EUCLID AVE, WESTFIELD, NJ 07090 (NAICS 238160). OSHA activity number 348578543.
Where did this inspection happen?
- Establishment
- NOVA'S PAINTING AND REMODELING LLC
- Site address
- 310 SOUTH EUCLID AVE
- City
- WESTFIELD
- State
- NJ
- ZIP
- 07090
- Mailing
- 21736 PINEWOOD CT, STERLING, VA 20164
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $4965.00 · Current $4965.00
General-duty citation text
29 CFR 1926.501(b)(13 ):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system: Nova's Painting and Remodeling LLC does not ensure that each employee is using appropriate fall protection while engaged in residential construction activities 6 feet (1.8 m) or more above lower levels. This violation was most recently observed, on or about November 3, 2025, at 310 South Euclid Ave Westfield, NJ: Instance A-Back Side of Roof) Employee #1 who was engaged in roofing activities on the two-story residential home when he fell to his death. The employee was exposed to a fall of approximately 18'11'' to the ground below as a personal fall arrest system, guardrail system, or safety net were not being used. The employee was wearing a harness as part of a personal fall arrest system; however, he was not tied off. Instance B-Back Side of Roof) Employee #1 who was engaged in roofing activities on the two-story residential home was using a harness that was designed for rock climbing and tree climbing and not a full-body harness for fall protection per Subpart M. The harness being used has a harness weight limit: 300KG. With a breaking strength of 15KN, which equals 3,372 pounds. The alloy buckets have a rated capacity of 18KN, which is equivalent to 4,000 pounds. The harness should have had Dee-rings and snap hooks with minimum tensile strength of 5,000 pounds (22.2 KN). Instance C-Back Side of Roof) Employee #1 who was engaged in roofing activities on the two-story residential home was using a hand ascender rope grab/clamp that was designed for rock climbing and tree climbing. The rope grab/clamp being used has a weight limit of 4KN and a breaking strength of 4 KN, which equals 899lbs. Connecting assemblies shall have a minimum tensile strength of 5,000 pounds (22.2 KN) Instance D-Back Side of Roof) Employee #1 who was engaged in roofing activities on the two-story residential home was using a ridge anchor that only had a total of four screws and or bolts securing it. User instruction manual for this type of roof anchor indicates the user to install 12d nails only and to use 10 nails per leg in order to obtain the 5,000lbs anchorage strength. Hazards noted on or about 11/03/25
Recent events (1)
- — Z (S) $4965
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $4965.00
General-duty citation text
29 CFR 1926.503(a)(1): The employer didn't provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards. A) 310 South Euclid Ave Westfield, NJ The employer didn't provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards. Hazards noted on or about 11/03/25
Recent events (1)
- — Z (S) $4965
1926.1053 B01
- Issued
- Penalty
- Initial $4965.00 · Current $4965.00
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access. A)310 South Euclid Ave Westfield, NJ Aluminum extension ladder which was being used to access the upper roof did not extend at least three feet above the upper landing surface of the roof. This condition exposed employees to fall hazards. Hazard noted on or about 11/3/2025
Recent events (1)
- — Z (S) $4965
More inspections in this industry (NAICS 238160)
PORTLAND, OR—2026-07-17 00:00:00
317744797 - JBC ROOFING LLC
MERIDIAN, ID—2026-07-17 00:00:00
COBRA'S ROOFING LLC
SYRACUSE, NY—2026-07-17 00:00:00
NAMICELA HOME SOLUTIONS INC
BRADLEY, IL—2026-07-16 00:00:00
JUAN CRUZ DBA ROOFBOYS LLC
PONCE INLET, FL—2026-07-16 00:00:00
RESOLUTE ROOFING LLC
More inspections in NJ
EAST ORANGE, NJ—2026-07-17 00:00:00
EAST ORANGE COMMUNITY CHARTER SCHOOL
EAST ORANGE, NJ—2026-07-17 00:00:00
EAST ORANGE COMMUNITY CHARTER SCHOOL
EAST ORANGE, NJ—2026-07-17 00:00:00
EAST ORANGE COMMUNITY CHARTER SCHOOL
MOUNTAIN LAKES, NJ—2026-07-17 00:00:00
JOHN CARUSO BUILDERS LLC
PENNINGTON, NJ—2026-07-16 00:00:00
BOROUGH OF PENNINGTON DEPARTMENT OF PUBLIC WORKS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348578543.