CHICAGO, IL —
OSHA Inspection: KRC CONSTRUCTION CORP.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of KRC CONSTRUCTION CORP. in 3726 N. RACINE, CHICAGO, IL 60613 (NAICS 238140). OSHA activity number 348607755.
Where did this inspection happen?
- Establishment
- KRC CONSTRUCTION CORP.
- Site address
- 3726 N. RACINE
- City
- CHICAGO
- State
- IL
- ZIP
- 60613
- Mailing
- 560 OLD OAK CIRCLE, ALGONQUIN, IL 60102
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.102 A01
- Issued
- Penalty
- Initial $2270.00 · Current $1100.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) On November 21, 2025, an employee was exposed to struck-by hazards while using a handheld gas-operated circular saw without wearing eye protection. No abatement documentation or certification is required for this item.
Recent events (2)
- — I (S) $1100
- — Z (S) $2270
1926.451 E01
- Issued
- Penalty
- Initial $3972.00 · Current $2300.00 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): Portable ladder, hook-on ladder, attachable ladder, stair tower, stairway-type ladder, ramp, runway, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used to access scaffold platforms more than 2 feet above or below a point of access: a) On November 21, 2025, employees were exposed to a fall hazards while accessing and egressing the work platform of a frame scaffold. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $2300
- — Z (S) $3972
1926.451 F06
- Issued
- Penalty
- Initial $3972.00 · Current $2300.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(6):Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note: Specify distances as indicated in table in paragraph (f)(6) of this section. a) On or about November 21, 2025, employees were exposed to electrical hazards while erecting, dismantling, and working from frame scaffolding in close proximity to a 120/240 volt overhead power line. No abatement documentation or certification is required for this item.
Recent events (2)
- — I (S) $2300
- — Z (S) $3972
1926.451 G01
- Issued
- Penalty
- Initial $3972.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) On November 21, 2025, employees working from frame scaffolding were exposed to fall hazards of greater than 25 feet. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $2000
- — Z (S) $3972
1926.1153 C01
- Issued
- Penalty
- Initial $3972.00 · Current $2300.00 Reduced
General-duty citation text
29 CFR 1926.1153(c)(1): For each employee engaged in a task identified on Table 1, the employer did not fully and properly implement the engineering controls, work practices, and respiratory protection specified for the tasks in Table 1, unless the employer assessed and limited the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section. a) On November 21, 2025, KRC Construction Corp., did not fully implement engineering controls and work practices, as specified in Table 1. An employee used a handheld power saw to cut brick containing up to 20% crystalline silica (quartz) without equipping the tool with a water delivery system that supplies a continuous stream or spray of water to the blade. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $2300
- — Z (S) $3972
1926.1153 D02 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1153(d)(2)(i): The employer did not assess the exposure of each employee who was or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2)(ii) or the scheduled monitoring option in paragraph (d)(2)(iii) of this section: a) On November 21, 2025, KRC Construction Corp. did not assess the exposure of an employee to respirable crystalline silica when cutting brick containing 20% crystalline silica. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1153 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1153(g)(1): The employer did not establish and implement a written exposure control plan that consists of at least the following elements: (i) A description of the tasks in the workplace that involve exposure to respirable crystalline silica; (ii) A description of the engineering controls used to limit employee exposure to respirable crystalline silica for each task; (iii) A description of the housekeeping measures used to limit employee exposure to respirable crystalline silica; and (iv) A description of the procedures used to restrict access to work areas, when necessary, to minimize the number of employees exposed to respirable crystalline silica and their level of exposure. a) On November 21, 2025, KRC Construction Corp., did not establish and implement a written silica exposure control plan that complied with the requirements of 1926.1153(g)(1)(i) through (iv) when an employee was using a handheld power saw to cut brick containing 20% crystalline silica. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16 00:00:00
DC MASONRY
WINNETKA, IL—2026-07-15 00:00:00
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15 00:00:00
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14 00:00:00
SUDLOW CONCRETE, INC.
FLAGLER BEACH, FL—2026-07-14 00:00:00
PLANET DESIGN SERVICES, INC.
More inspections in IL
DEERFIELD, IL—2026-07-16 00:00:00
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16 00:00:00
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16 00:00:00
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16 00:00:00
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16 00:00:00
B & M PLASTIC INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348607755.