Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NELSON WIRE ROPE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NELSON WIRE ROPE in 3051 PENN STREET, HATFIELD, PA 19440 (NAICS 332618). OSHA activity number 348628546.

Watch Nelson Wire Rope — free Get an email when a new federal OSHA severe-injury report for Nelson Wire Rope is published. One employer, no account, unsubscribe in one click.
Establishment
NELSON WIRE ROPE
Site address
3051 PENN STREET
City
HATFIELD
State
PA
ZIP
19440
Mailing
3051 PENN STREET, HATFIELD, PA 19440
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332618
Employees
10
Ownership type
A

2 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2270.00 · Current $1703.00 Reduced
29 CFR  1910.147(c)(1):  Energy control program. The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  a)  Nelson Wire Rope 3051 Penn Street Hatfield, PA 19440:  On or about December 5, 2025 employees performing minor maintenance on machinery such as Swager presses were exposed to hazards because the employer did not establish a written energy control program consisting of an energy control procedure, employee training, and periodic inspections.  No Lock-Out-Tag-Out program was in place at the time of the inspection.
Recent events (2)
  • — I (S) $1702.5
  • — Z (S) $2270

1910.303 G01

Other-than-serious 1 instance 10 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(g)(1):  Space about electric equipment. Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.  a)  Nelson Wire Rope 3051 Penn Street Hatfield, PA 19440:  On or about December 5, 2025 the employer did not ensure that sufficient access and working space was provided and maintained for all electrical panels.  The electrical service panels were blocked by equipment, stacked battery chargers, and a spool of wire.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0