105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #1000413

AMPUTATED,POWER PRESS,FINGER,WORK RULES,CAUGHT BY,LACERATION,POINT OF OPERATION,PRESS OPERATOR,UNGUARDED

Event
AMPUTATED,POWER PRESS,FINGER,WORK RULES,CAUGHT BY,LACERATION,POINT OF OPERATION,PRESS OPERATOR,UNGUARDED
Linked inspection
No inspection record linked to this accident's victims.
Summary number
1000413
Report ID
453710

Event description

Employee's fingers amputated in power press

Investigation abstract

Employee #1, the operator of a full-revolution mechanical power press, was inser ting and removing small parts from the point of operation by hand. The press was activated by a foot pedal without a single stroke mechanism and had no point of operation guards or devices. Employee #1 had reached into the point of operatio n to remove a part when the press activated and caught her right index and middl e fingers. Her right index fingertip was lacerated and a small portion of her ri ght middle fingertip was amputated.

Victim

  1. #1 Non-hospitalized injury Age 22 F

    Nature of injury
    1
    Part of body
    10
    Event type
    2
    Source
    26
    Occupation code
    706
    Human factor
    6
    Environmental factor
    1
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.