SHEARING MACHINE,AMPUTATED,FINGER,GUARD,PRESS

Event
SHEARING MACHINE,AMPUTATED,FINGER,GUARD,PRESS
Linked inspection
No inspection record linked to this accident's victims.
Summary number
1001346
Report ID
751910

Event description

EMPLOYEE'S FINGER AMPUTATED BY MACHINE WITH A BROKEN GUARD

Investigation abstract

AT 7:15 AM ON DECEMBER 16, 1986, EMPLOYEE #1 WENT TO A METAL SHEAR IN DEPT. 740 TO CUT A SMALL PIECE OF METAL WITH THE SHEAR CUTOFF PRESS. A ROLLER ON THE GUARD IN FRONT OF THE HOLD-DOWN CYLINDERS WAS MISSING, LEAVING A 1 1/2 INCH BY 2 3/4 INCH AREA UNDER THE HOLD-DOWN HYDRAULIC CYLINDERS WHERE EMPLOYEE #1 COULD PLACE HIS FINGERS. THE MACHINE WAS A HTE SHEAR (MODEL 500-80) SERIAL #A6771169. THE BL ADE WAS 3 INCHES BEHIND THE HYDRAULIC HOLD-DOWN. THE MISSING ROLLER HAD BEEN REP LACED BY THE TIME OF THE INVESTIGATION. THE EMPLOYEE'S RIGHT LITTLE FINGER WAS A MPUTATED AT ITS MIDPOINT. HIS LEFT LITTLE FINGER WAS AMPUTATED, LEAVING THE NAIL INTACT.

Victim

  1. #1 Hospitalized Age 43 M

    Nature of injury
    1
    Part of body
    10
    Event type
    2
    Source
    26
    Occupation code
    645
    Human factor
    1
    Environmental factor
    4
    Task assigned
    2