105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #119958916

AMPUTATED,INADEQUATE MAINT,FINGER,WORK RULES,CONSTRUCTION,VIBRATIONS,V-BELT,PULLEY,LOST BALANCE,UNGUARDED

Event
AMPUTATED,INADEQUATE MAINT,FINGER,WORK RULES,CONSTRUCTION,VIBRATIONS,V-BELT,PULLEY,LOST BALANCE,UNGUARDED
Linked inspection
No inspection record linked to this accident's victims.
Summary number
119958916
Report ID
950633

Event description

Employee's fingers amputated in V-belt pulley system

Investigation abstract

At approximately 4:00 p.m. on July 21, 1997, Employee #1 was measuring and insta lling insulation on a chilled water pipe as part of contractual obligation for a nother employer. He was taking measurements when he momentarily lost his balance and his right index finger was amputated in the nip point of the unguarded V-be lt and pulley drive adjacent to where he was standing. He was given first aid an d transported to Ridgecrest Community Hospital for treatment. The guard had fall en off the machine when the bolts supporting the guard's mounting brackets backe d out due to heavy vibrations.

Victim

  1. #1 Non-hospitalized injury Age 36 M

    Nature of injury
    1
    Part of body
    10
    Event type
    2
    Source
    26
    Occupation code
    593
    Human factor
    9
    Environmental factor
    3
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.