104,543Records 70,659Employers 84,666Hospitalizations 27,563Amputations 2015-01-01 2025-09-30
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #14200240

AMPUTATED,FINGER,TWO-HAND CONTROL,PUNCH PRESS,AUTOMATIC RESTART,HAND

Event
AMPUTATED,FINGER,TWO-HAND CONTROL,PUNCH PRESS,AUTOMATIC RESTART,HAND
Linked inspection
No inspection record linked to this accident's victims.
Summary number
14200240
Report ID
352420

Event description

EMPLOYEE'S TIP OF MIDDLE FINGER AMPUTATED IN PUNCH PRESS

Investigation abstract

On January 29, 1985, Employee #1, a press operator, was manufacturing ceramic pa tic mode so that the two-hand button control would only have to be touched once. He reached inside the front opening to retrieve the manufactured ceramic parts. He placed the tip of his middle finger of his right hand over the die cavity, a nd it was amputated by the press. rts. The employee was using a Mohr compacting press Model Number m-15, Serial Nu mber K15-84-1, manufactured 8-84. The compacting press had a two-hand button con trol located in a control console separate from the press. The press was enclose d by interlocking glass doors except for the front operator's location, which ha d an opening 12 in. wide and 31 in. high. In the press, a metal feeder shoe move d from back to front, loaded the die, and pushed forward the ceramic part that h ad just been formed. Employee #1 had to reach 10 in. inside the front opening to retrieve the manufactured ceramic parts. Employee #1 placed the press on automa

Victim

  1. #1 Hospitalized Age 26 M

    Nature of injury
    1
    Part of body
    10
    Event type
    1
    Source
    26
    Occupation code
    706
    Human factor
    1
    Environmental factor
    3
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.