104,543Records 70,659Employers 84,666Hospitalizations 27,563Amputations 2015-01-01 2025-09-30
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #14200463

POWER PRESS,FINGER,GUARD,MACHINIST,CRUSHED

Event
POWER PRESS,FINGER,GUARD,MACHINIST,CRUSHED
Linked inspection
No inspection record linked to this accident's victims.
Summary number
14200463
Report ID
352420

Event description

FINGERS CRUSHED BY POWER PRESS

Investigation abstract

A machine operator was machining 0.625-in. diameter C/89 retaining rings on a tw d fingers were caught between the dies and crushed. He was hospitalized. o-ton Farrel No. 2 mechanical power press. The employee used two foot pedals, on e to actuate the press and the other to actuate compressed air. The upper die wa s 2.25 in. by 1 in. and the lower die was 3 in. by 2.25 in. The distance between the dies was one in. The rings were hand fed into position and actuated between the dies. During a batch process, one of the rings rolled out of the point of a ctuation. The employee attempted to push the ring back into proper position by u sing his left hand to flick the ring back to the point of actuation. While attem pting this, he accidentally actuated the press and his index and middle left han

Victim

  1. #1 Hospitalized Age 47 M

    Nature of injury
    7
    Part of body
    10
    Event type
    2
    Source
    26
    Occupation code
    706
    Human factor
    9
    Environmental factor
    1
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.