104,543Records 70,659Employers 84,666Hospitalizations 27,563Amputations 2015-01-01 2025-09-30
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #14201479

AMPUTATED,SPINE,BROOM,CAUGHT BETWEEN,PELVIS,ARM,CHEMICAL

Event
AMPUTATED,SPINE,BROOM,CAUGHT BETWEEN,PELVIS,ARM,CHEMICAL
Linked inspection
No inspection record linked to this accident's victims.
Summary number
14201479
Report ID
352410

Event description

EMPLOYEE'S ARM AMPUTATED BY RIBBON AGITATOR OF BATCH BLENDER

Investigation abstract

Employee #1 and other employees were cleaning a dry powdered agricultural chemic utated. al from a horizontal batch blender using hand held brooms. The body of the blend er was 14 ft long, 4 ft 6 in. wide and 5 ft 6 in. deep with a full length horizo ntal ribbon agitator and a wide center cover. Employee #1 removed the center cov er and stood inside the body of the blender, leaning partially under a 5-ft-wide fixed end cover to clean underneath it with a broom. There was an unintentional partial revolution of the electric motor powered agitator causing Employee #1 t o be caught between the inside of the blender and the ribbon agitator. The emplo yee suffered from a broken pelvis, injury to his spine and his right arm was amp

Victim

  1. #1 Hospitalized Age 28 M

    Nature of injury
    1
    Part of body
    2
    Event type
    2
    Source
    26
    Occupation code
    863
    Human factor
    13
    Environmental factor
    4
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.