104,543Records 70,659Employers 84,666Hospitalizations 27,563Amputations 2015-01-01 2025-09-30
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #14206908

ELEC PROTECT EQUIP,OVERHEAD POWER LINE,ELECTRICAL,ELECTROCUTED,E PTD,ELEC UTILITY WORK,AERIAL LIFT

Event
ELEC PROTECT EQUIP,OVERHEAD POWER LINE,ELECTRICAL,ELECTROCUTED,E PTD,ELEC UTILITY WORK,AERIAL LIFT
Linked inspection
No inspection record linked to this accident's victims.
Summary number
14206908
Report ID
1054116

Event description

ELECTRIC SHOCK - DIRECT CONTACT WITH OVERHEAD POWER LINE

Investigation abstract

AN EMPLOYEE WAS REPAIRING A LIGHTNING-CAUSED POWER OUTAGE ON A POLE LOCATED 32 F EET FROM A HIGHWAY. THE EMPLOYEE WAS USING AN INTERNATIONAL DOUBLE-BUCKET LINE T RUCK WITH AN ALTEC 50-FOOT EXTENSIBLE BOOM (MODEL NO. AA600; SERIAL NO. 0881-101 48). HE HELD THE BURNT PORTION OF THE LEFT TAP LINE IN HIS LEFT HAND. AS HE REAC HED TO CUT OFF ANOTHER LINE WITH HIS WIRE CUTTERS, HE CONTACTED THE TOP OF A 12- KILOVOLT CUTOUT OR A JUMPER WIRE WITH THE BACK OF HIS RIGHT WRIST. THE EMPLOYEE WAS ELECTROCUTED.

Victim

  1. #1 Fatality Age 41 M

    Nature of injury
    10
    Part of body
    12
    Event type
    13
    Source
    15
    Occupation code
    577
    Human factor
    1
    Environmental factor
    18
    Task assigned
    2

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.