BURN,CLOTHING,ELECTRICAL,FIRE,IGNITION SYSTEM,E C,GASOLINE,ELECTRIC GENERATOR,GAS CAN,NON-APPROVED GAS CAN

Event
BURN,CLOTHING,ELECTRICAL,FIRE,IGNITION SYSTEM,E C,GASOLINE,ELECTRIC GENERATOR,GAS CAN,NON-APPROVED GAS CAN
Linked inspection
No inspection record linked to this accident's victims.
Summary number
14211379
Report ID
352440

Event description

FIRE - IGNITION WIRING IGNITED GAS SPILLED FROM UNAPPRVD CAN

Investigation abstract

AN EMPLOYEE WAS FILLING A DAYTON GASOLINE-POWERED GENERATOR WITH 1 GALLON OF GAS FOREARM. THERE WAS NO LOST TIME. THE EMPLOYEE WAS A GLAZIER. REFUELING THE GENER ATOR WAS PART OF HIS JOB. HE HAD EARLIER ASKED ABOUT THE WHEREABOUTS OF THE SPOU T BUT HAD USED THE CAN WITHOUT THE SPOUT ANYHOW. OLINE FROM A 2.5-GALLON NON-APPROVED SPOUTLESS GAS CAN. HE SPILLED GASOLINE OVER THE GENERATOR'S FUEL TANK AND ONTO THE MOTOR AND WIRING. HE REPLACED THE FUEL C AP AND STARTED THE GENERATOR. SPARKS FROM THE WIRING OR SPARK PLUG IGNITED THE G ASOLINE VAORS AND SET FIRE TO THE GENERATOR. THE PORTABLE GENERATOR MEASURED ABO UT 30 INCHES LONG BY 14 INCHES HIGH BY 17 INCHES WIDE, AND IT HAD A 1 GALLON GAS TANK. (IT WAS A DAYTON MODEL 159, 3500 WATT, 240 VOLT; SN 3W0141.) THE WEATHER WAS 88 DEGREES F, HIGH HUMIDITY, WINDS 4 - 8 MPH (FROM AIRPORT WEATHER REPORT). THE INJURED EMPLOYEE SUSTAINED FIRST DEGREE BURNS ON HIS RIGHT HAND, WRIST, AND

Victim

  1. #1 Hospitalized Age 26 M

    Nature of injury
    5
    Part of body
    2
    Event type
    14
    Source
    16
    Occupation code
    589
    Human factor
    9
    Environmental factor
    10
    Hazardous substance
    1340
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.